ZLF / ZLV distance protection terminal for HV lines

ZLF and ZLV provide distance protection for overhead and cable lines of any voltage class, including parallel lines and lines with series capacitor compensation. ZLF has 8 zones with Mho and quadrilateral characteristics, ZLV has up to 6 reverse zones, and the operating time is less than one cycle.

Zones
ZLF: 8 zones (Mho / quadrilateral characteristic); ZLV: up to 6 reverse zones
Operating time
less than one cycle (subcycle)
Tripping
single-phase and three-phase, one or two circuit breakers
Teleprotection schemes
DTT, PUTT, POTT, DCUB, DCB

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The terminals trip faults on a single-phase or three-phase basis and control one or two circuit breakers of the bay. To speed up tripping, teleprotection schemes DTT, PUTT, POTT, DCUB and DCB are available, working together with communication channel equipment. Separate functions monitor power swings, VT circuit failures and operation on lines with series compensation. Communication with the substation control system uses IEC 61850 Ed.2. The terminals suit lines of any configuration, overhead and cable.

Technical specifications

ZonesZLF: 8 zones (Mho / quadrilateral characteristic); ZLV: up to 6 reverse zones
Operating timeless than one cycle (subcycle)
Trippingsingle-phase and three-phase, one or two circuit breakers
Teleprotection schemesDTT, PUTT, POTT, DCUB, DCB
Additionalpower swing, VT circuit failure, series compensation
ProtocolIEC 61850 Ed.2

Request a price and lead time

ZLF / ZLV distance protection terminal for HV lines. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8536 49 00 90
HS, 6 digits8536 49
CN (EU)8536 49 00
HTSUS (USA)8536 49 00 80
China customs tariff8536 49 00 90

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

How many distance protection zones do ZLF and ZLV have?

ZLF has 8 zones with Mho or quadrilateral characteristics, ZLV has up to 6 reverse zones.

Which teleprotection schemes are supported?

DTT, PUTT, POTT, DCUB and DCB. Tripping is single-phase and three-phase, on one or two circuit breakers.

Is the terminal suitable for lines with series compensation?

Yes, the terminals are designed for parallel lines and lines with series capacitor compensation, and also provide power swing and VT circuit supervision.