XMORE XMR-D — generator and motor protection with differential protection

XMR-D is a terminal of the XMORE platform for protection of motors and generators, including differential protection. The hardware and software are modular, so the terminal scales to the task. It is used at small and medium power plants and for large pump and compressor motors.

Object
generators, motors (including with a transformer)
Analog inputs
up to 12
Differential protection
with dual-slope characteristic, 87G/87M/87T
Functions
40, 78, 50/27, 51V, 32P/Q, 37P/Q, 64REF, 66, 49MG, 67N, 81R, 25

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The main protection of XMR-D is differential, with restraint and a dual-slope characteristic. It is applied to a generator, motor or transformer (87G, 87M, 87T). Like other XMORE devices, the terminal is modular in hardware and software, so the configuration is selected for the specific installation.

A set of machine functions is added to the differential protection: loss of excitation (40), out-of-step (78), inadvertent energization of a stationary machine (50/27), overcurrent protection with voltage control or restraint (51V), active and reactive power direction protections, including reverse power and underpower (32P, 32Q, 37P, 37Q), low-impedance restricted earth fault protection (64REF), start count limiting (66), a motor/generator thermal model (49MG), supervision of the negative-to-positive sequence current ratio (I2/I1), directional earth fault protection (67N), rate-of-change-of-frequency protection (81R), phase sequence supervision (47) and synchronism check (25).

The terminal also provides overcurrent protection, frequency and zero-sequence voltage protections, trip circuit supervision and other functions. Thermal protection via Pt100 sensors and an arc flash protection function are available as options. There are up to 12 analog inputs, power and energy metering is performed with an accuracy class of up to 0.5. Fault recording runs at 32 samples per cycle, and measurement for protections at 64 samples per cycle.

For accurate recording of the sequence of events (SOE), time synchronization via PTP (IEC 1588) and SNTP is supported. Communication security is supported by the HSR, PRP and RSTP redundancy protocols and a built-in cybersecurity package. The devices work with IEC 61850 Ed.1/Ed.2, IEC 60870-5-103, Modbus (serial and TCP) and DNP3 (serial and TCP); a DNV certificate confirms compliance of the IEC 61850 Ed.2 server for XMR-P, XMR-A, XMR-D, XMR-T and XMR-V. The terminal is installed on synchronous generators of small and medium power plants (hydro, CHP, gas engine and diesel units) and on generator-transformer units of industrial facilities.

Technical specifications

Objectgenerators, motors (including with a transformer)
Analog inputsup to 12
Differential protectionwith dual-slope characteristic, 87G/87M/87T
Functions40, 78, 50/27, 51V, 32P/Q, 37P/Q, 64REF, 66, 49MG, 67N, 81R, 25
OptionsPt100 thermal protection, arc flash protection
Meteringaccuracy class up to 0.5
Fault recorder32 samples/cycle; measurement 64 samples/cycle
SynchronizationPTP (IEC 1588), SNTP
RedundancyHSR, PRP, RSTP
ProtocolsIEC 61850 Ed.1/Ed.2, IEC 60870-5-103, Modbus, DNP3

Request a price and lead time

XMORE XMR-D — generator and motor protection with differential protection. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What differential protection does XMR-D have?

Differential protection with restraint and a dual-slope characteristic for a generator, motor or transformer (87G, 87M, 87T).

How many analog inputs does XMR-D have?

Up to 12 analog inputs. Power and energy metering is performed with an accuracy class of up to 0.5.

Which protocols and time synchronization does XMR-D support?

IEC 61850 Ed.1/Ed.2, IEC 60870-5-103, Modbus and DNP3. Time is synchronized via PTP (IEC 1588) and SNTP, with HSR, PRP and RSTP redundancy.