International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

WR70x175S(P)…WR200x500S(P) rectangular measuring current transformers

WR…S and WR…SP rectangular transformers turn AC currents into evaluable signals for RCM and RCMS monitors and EDS insulation fault locators. The SP types carry integrated screening for busbar systems.

Type
Rectangular measuring current transformer
Without screening (S)
WR70x175S, WR115x305S, WR150x350S, WR200x500S
With screening (SP)
WR70x175SP, WR115x305SP, WR150x350SP, WR200x500SP
Rated transformation ratio
600/1

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Highly sensitive rectangular transformers of the WR…S series work with RCM and RCMS residual current monitors and evaluators. Combined with EDS insulation fault location systems in IT systems, they measure the locating current from a PGH injector or an ISOMETER® IRDH. A two-wire cable runs to the connected device.

Compatible devices are RCMS460/490 and RCMS470 systems, RCM420, RCM460 and RCM470 monitors, and EDS440, EDS460/490 and EDS470 locators in AC and DC systems. The WR…SP types have integrated screening, which prevents false tripping of connected RCM… or EDS… devices when high load or inrush currents occur. They suit busbar systems and are intended for load currents ≥ 500 A.

Four opening sizes are made: WR70x175, WR115x305, WR150x350 and WR200x500, each without screening (S) or with it (SP). The rated transformation ratio is 600/1, rated burden 180 Ω, nominal power 50 mVA, rated frequency 50…400 Hz, internal resistance 5…8 Ω and accuracy class 5.

Rated continuous thermal current is 100 A, short-time 14 kA/1 s and surge 50 kA/50 ms. Highest system voltage Um is AC 720 V and rated impulse withstand voltage Uisol 3 kV. A P6KE6V8CP suppressor diode protects the secondary side. Ambient temperature in operation is - 10 °C…+ 50 °C, climatic class 3K22 to IEC 60721-3-3.

Terminals are screw-type, protection is IP40 for internal components and IP20 for terminals, and flammability class is UL94 V-0. Any mounting position is allowed. The transformers comply with DIN EN 60044-1. Only qualified electricians should install them.

Technical specifications

TypeRectangular measuring current transformer
Without screening (S)WR70x175S, WR115x305S, WR150x350S, WR200x500S
With screening (SP)WR70x175SP, WR115x305SP, WR150x350SP, WR200x500SP
Rated transformation ratio600/1
Rated burden180 Ω
Rated primary current≤ 10 A (100 A) / ≥ 10 mA
Nominal power50 mVA
Rated frequency50…400 Hz
Internal resistance5…8 Ω
Accuracy class5
Rated continuous thermal current100 A
Rated short-time thermal current14 kA/1 s
Rated surge current50 kA/50 ms
Highest system voltage UmAC 720 V
Rated impulse withstand voltage Uisol3 kV
Ambient temperature (operation)- 10 °C…+ 50 °C
Degree of protectionIP40 (internal components), IP20 (terminals)
Flammability classUL94 V-0

Part numbers

Show all part numbers (8)

B911738, B911739, B911740, B911763, B911790, B911791, B911792, B911793

How it compares with similar models

ParameterWR70x175S(P)…WR200x500S(P) rectangular measuring current transformersWS50x80S…WS80x160S split-core current transformers for residual currents of 10 mA…100 AW0-S20…W5-S210 and W10/600 measuring current transformers for residual currents up to 100 ALINETRAXX® CTAC20, CTAC35, CTAC60, CTAC120 and CTAC210 measuring current transformers
TypeRectangular measuring current transformerSplit-core measuring current transformerMeasuring current transformerMeasuring current transformer
Rated burden180 Ω180 Ω180 Ω (18 Ω at 100 A)—
Rated frequency50…400 Hz50…400 Hz15…400 Hz—
Accuracy class553—
Rated short-time thermal current14 kA/1 s14 kA/1 s14 kA 1 s—

Request a price and lead time

WR70x175S(P)…WR200x500S(P) rectangular measuring current transformers. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What is the difference between S and SP types?

SP types have integrated screening, which prevents false tripping of RCM… or EDS… devices at high load and inrush currents. They are used in busbar systems for load currents ≥ 500 A.

Which devices do the WR…S(P) transformers work with?

RCMS460/490, RCMS470, RCM420, RCM460, RCM470, and EDS440, EDS460/490 and EDS470. A two-wire cable makes the connection.

Which opening sizes are available?

70 x 175 mm, 115 x 305 mm, 150 x 350 mm and 200 x 500 mm, each as an S and an SP type.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides