SPRECON-EDIR — directional earth fault and short-circuit indicator for MV networks

SPRECON-EDIR is a directional earth fault and short-circuit indicator for continuous monitoring of 10–35 kV MV networks. It works in compensated, isolated and solidly earthed networks and applies several fault localization methods at the same time. The function is available as a separate panel-mounted device and as a software module in SPRECON-E-P DS6 and DD6 devices.

Networks
compensated, isolated, solidly earthed MV networks
Function
continuous monitoring, several fault localization methods at the same time, prioritization into one message
Versions
separate device in a panel housing according to IEC 61554, 96×48×90 mm; software module in SPRECON-E-P DS6 and DD6

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The indicator is installed at distribution substations, sectionalizing points and digital transformer substations so that the dispatcher can quickly find the faulted section of a line. The device analyzes several different methods of determining the direction and location of an earth fault at the same time. The results of individual methods can be combined with priorities into one final message, and localization becomes more reliable than with a single method. Short circuits are detected by the same device.

The EDIR function exists in three forms. The separate SPRECON-EDIR device has a panel housing according to IEC 61554 measuring 96×48×90 mm (W×H×D). The same function is built in as a software module in the SPRECON-E-P DS6 series (combined overcurrent protection and control devices) and the SPRECON-E-P DD6 series (combined distance protection and control devices). The software is the same for all series and is based on SPRECON-EDIR, so the fault indication logic is identical in all versions. The separate device is convenient where feeder protection is already installed and is not planned to be replaced.

In combined SPRECON-E-P devices the EDIR function runs at a lower priority than the main protection function of the device. Control, earth fault indication and protection in these devices are consistently separated, so the functions do not influence one another. Protection, control and the fault indicator are then combined in one bay device.

Measuring circuits are connected through adapters. There is an adapter for low-power instrument transformers of 3.25/√3 V AC according to IEC 61869-10/11, and adapters for conventional secondary circuits of 100, 110, 115 and 120 V AC. The manufacturer positions the device equally for digital transformer substations and for medium voltage installations. It has the automation, network communication and IT security functions needed to operate as part of a digital network.

The indicator is designed for 10–35 kV networks, including those with arc suppression coils, where it is used together with the SPRECON-E-EREG regulator. Together with the SPRECON platform for control, protection and remote control and the SPRECON-V460 visualization, it forms part of a distribution network automation system. The manufacturer publishes a separate document, Advanced directional indication of earth faults and short circuits (SPRECON-EDIR).

Technical specifications

Networkscompensated, isolated, solidly earthed MV networks
Functioncontinuous monitoring, several fault localization methods at the same time, prioritization into one message
Versionsseparate device in a panel housing according to IEC 61554, 96×48×90 mm; software module in SPRECON-E-P DS6 and DD6

Request a price and lead time

SPRECON-EDIR — directional earth fault and short-circuit indicator for MV networks. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8537 10 98 00
HS, 6 digits8537 10
CN (EU)8537 10 98
HTSUS (USA)8537 10 91 70
China customs tariff8537 10 90 90

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

In networks with which neutral treatment does SPRECON-EDIR work?

In compensated, isolated and solidly earthed 10–35 kV MV networks. In networks with arc suppression coils it is used together with the SPRECON-E-EREG regulator.

Which versions of the EDIR function are available?

A separate device in a panel housing according to IEC 61554 measuring 96×48×90 mm, and a software module in SPRECON-E-P DS6 and DD6 devices. The software is the same in all versions.

Does EDIR affect the protection functions of a combined SPRECON-E-P device?

No, in SPRECON-E-P the EDIR function runs at a lower priority than the main protection. The control, fault indication and protection functions are separated and do not influence one another.