SO-52v11-eMTZR, SO-54SR-141/4xx/5xx — digital MV protection with bay controller functions
Digital protection relays from the manufacturer for medium-voltage distribution networks, combined with bay controller and telemechanics functions. The SO-52v11-eMTZR serves a switchgear bay, and the SO-54SR-141 controls an indoor circuit breaker in an MV network. They are used in switchgear bays and sectionalizing points of 6–30 kV.
- SO-52v11-eMTZR
- protection + bay controller: measurement, protection, control, telemechanics, automation (AR), multichannel disturbance recorder
- eMTZR modules
- MPA (4 fast outputs for breaker coils), MWS (up to 32 inputs 220/110/24 V DC), MSS-2xx (12 outputs), MZA, KWG terminal with a touch screen
- SO-54SR-141
- field controller with protection for an indoor circuit breaker; touch LCD, 8 LEDs, ON/OFF buttons; GPRS/UMTS MSG-61x; 24 V battery
- Communication channels
- GPRS/UMTS-APN, TETRA, CDMA2000, DMR, dedicated lines
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The SO-52v11-eMTZR combines measurement, protection, control, telemechanics, automation and a multichannel disturbance recorder, and provides complete servicing of the circuit breaker. It detects short-circuit currents, clears faults by operating the breaker and recloses the line with auto-reclosing (AR). The reaction time to a short circuit is 14–18 ms. The controller directly operates the apparatus of a typical bay, that is the breaker and three disconnectors, and the interlocking equations are defined in the logic module. The protection functions include earth-fault current protection, directional and admittance. Four setting banks simplify the operation of industrial switchgear, the event log helps establish the causes of trips, and recorder data go to the analysis of disturbance events in the network.
The design is modular. The MPA measurement and communication module measures currents and voltages, maintains communication with external devices and has 4 fast high-power relay outputs for direct control of breaker coils. The MWS module records events and counts pulses (up to 32 inputs for 220, 110 or 24 V DC), and the MSS-2xx module has 12 fully isolated relay outputs for an operating voltage of up to 220 V DC. The set also includes the MZA power supply unit and the KWG terminal with a large graphic display, a touch panel, a local/remote control switch and LED signaling. Communication runs over optical Ethernet FX100, RS-485 or serial optical channels, including under PN-EN 61850.
The SO-54SR-141 field controller with protection functions is installed on an indoor circuit breaker. It clears disturbances in the MV network caused by single-phase and multi-phase faults, operates the breaker remotely from SCADA or locally with buttons and a touch LCD screen, and performs telemechanics, signal concentration and software interlocking against conflicting commands. Protection settings are changed from the panel or with a dedicated program. The controller is mounted in the breaker control cabinet together with the MSG-61x GPRS/UMTS-APN module, a 24 V DC battery with a charger, a heater with a thermostat, buttons, mode switches (AR, live-line work) and terminals.
The controller communicates with SCADA over GPRS/UMTS-APN, TETRA, CDMA2000 or DMR radio channels, or over dedicated lines. The SO-54SR series also covers versions -301, -321, -351, -401, -421, -424, -501, -521 and -524 for disconnectors and breakers of overhead lines and MV points, which are described in separate entries. For example, the SO-54SR-321-WL works in networks with compensated, resistor-earthed or isolated neutral and has cybersecurity mechanisms under PN-EN 62351.
Technical specifications
| SO-52v11-eMTZR | protection + bay controller: measurement, protection, control, telemechanics, automation (AR), multichannel disturbance recorder |
|---|---|
| eMTZR modules | MPA (4 fast outputs for breaker coils), MWS (up to 32 inputs 220/110/24 V DC), MSS-2xx (12 outputs), MZA, KWG terminal with a touch screen |
| SO-54SR-141 | field controller with protection for an indoor circuit breaker; touch LCD, 8 LEDs, ON/OFF buttons; GPRS/UMTS MSG-61x; 24 V battery |
| Communication channels | GPRS/UMTS-APN, TETRA, CDMA2000, DMR, dedicated lines |
| SO-54SR series | -301/321/351/401/421/424/501/521/524 |
Request a price and lead time
SO-52v11-eMTZR, SO-54SR-141/4xx/5xx — digital MV protection with bay controller functions. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Customs codes
| UKTZED (Ukraine) | 8537 10 98 00 |
|---|---|
| HS, 6 digits | 8537 10 |
| CN (EU) | 8537 10 98 |
| HTSUS (USA) | 8537 10 91 70 |
| China customs tariff | 8537 10 90 90 |
Codes are for reference: the final code is determined at declaration for the specific model.
Questions and answers
Which functions does the SO-52v11-eMTZR combine?
Measurement, protection, control, telemechanics, AR automation and a multichannel disturbance recorder. The MPA module has 4 fast outputs for breaker coils.
For what voltage are these protection relays intended?
For MV distribution networks, in particular switchgear bays and sectionalizing points of 6–30 kV.
Over which channels does the SO-54SR-141 communicate with SCADA?
Over GPRS/UMTS-APN, TETRA, CDMA2000 or DMR radio channels, or over dedicated lines. The MSG-61x module and a 24 V DC battery are installed in the cabinet.
Similar equipment from other manufacturers