International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

Smartline S24 — multifunction protection relays for MV feeders

The Smartline S24 range of multifunction digital relays for medium-voltage distribution and industrial networks. Used as primary protection of lines and transformers and as backup protection of motors and generators. Versions S24/F, Fr, G, L, LD, T, U and HZ, 24 HP case.

Versions
S24/F, S24/Fr, S24/G, S24/L, S24/LD, S24/T, S24/U, S24/HZ, S24/DG
Current inputs
4 (3×1/5 A + 1×1/5/0.2 A); 8 in S24/T
Voltage inputs
4 (Fr, G, L, U)
Binary inputs/outputs
6 / 5 (standard), 2 fast trip outputs 4 A

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The S24 relays are built on a modular hardware platform with an economical set of modules. They are available in several standard configurations that are ready for operation right after the settings are entered. The relays are used as primary protection of overhead and cable lines, as protection of transformers and generator-transformer units, and as backup protection of motors, transformers and generators where an independent backup system is required. Networks with isolated, resistance-grounded, compensated and solidly grounded neutral are supported.

S24/F protects feeders and incomers with overcurrent protection, as well as induction motors (thermal model, negative sequence, undercurrent, start supervision); capacitor bank protection, auto-reclosing and breaker failure protection can be added as options. S24/Fr additionally has voltage protections for networks with low generation. S24/G adds loss-of-excitation protection to Fr and is designed for generators of 3–15 MW. S24/L provides line protection with distance protection. S24/LD provides longitudinal differential protection of lines and cables up to 50 km over single-mode fibre. S24/T provides differential protection of two-winding transformers and generator-transformer units. S24/U implements voltage and frequency protections and synchronism check. S24/HZ is high-impedance differential protection of busbars, transformers, generators and motors.

Hardware: 4 current inputs (3×1/5 A and 1×1/5/0.2 A with a sensitive channel), 8 in S24/T; 4 voltage inputs in versions with voltage measurement. As standard there are 6 binary inputs, 5 outputs, 2 fast trip outputs rated 4 A and a fault contact. The disturbance recorder stores up to 8 analogue and 32 binary channels, and the event log holds 1000 events with time stamps in non-volatile memory. Trip circuit supervision and self-diagnostics with blocking on failure are provided.

Communication via IEC 61850 with horizontal GOOSE exchange, IEC 60870-5-101, IEC 60870-5-103 and Modbus RTU. The 24 HP case allows flush, semi-flush or DIN-rail mounting, with IP54 protection at the front and IP20 at the rear. S24 relays are also field devices of the SIRACUS 2+ ring reconfiguration system. For many tasks the standard configuration is sufficient, so setup comes down to entering the settings.

Technical specifications

VersionsS24/F, S24/Fr, S24/G, S24/L, S24/LD, S24/T, S24/U, S24/HZ, S24/DG
Current inputs4 (3×1/5 A + 1×1/5/0.2 A); 8 in S24/T
Voltage inputs4 (Fr, G, L, U)
Binary inputs/outputs6 / 5 (standard), 2 fast trip outputs 4 A
Recorder8 analogue and 32 binary channels
Event log1000 events
ProtocolsIEC 61850 (GOOSE), IEC 60870-5-101/103, Modbus RTU
Degree of protectionIP54 at the front, IP20 at the rear
Case24 HP, flush, semi-flush, DIN rail
S24/LDprotected line length up to 50 km over single-mode fibre
S24/Ggenerators of 3–15 MW

Request a price and lead time

Smartline S24 — multifunction protection relays for MV feeders. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which current inputs do the S24 relays have?

Four inputs, 3×1/5 A and 1×1/5/0.2 A with a sensitive channel. S24/T has 8 current inputs.

What line length is S24/LD designed for?

Longitudinal differential protection works on lines and cables up to 50 km over single-mode fibre.

What case and degree of protection do the S24 relays have?

A 24 HP case with flush, semi-flush or DIN-rail mounting. The degree of protection is IP54 at the front and IP20 at the rear.