РВЦ-03-2 weekly and daily cycle timer, 3 channels, 60 settings
The РВЦ-03-2 is a three-circuit cyclic time relay that runs a daily or weekly on-off programme. It offers three channels, up to 60 settings and three changeover contacts rated 8 A, with a clock reserve of at least 150 h.
- Control channels
- 3
- Maximum number of settings
- 60
- Programme cycle
- daily, weekly
- Rated supply voltage
- AC/DC 24-42; AC/DC 110-240
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The РВЦ-03-2 switches household and industrial appliances on and off to a preset programme in real time. It works as a timer with a weekly or daily cycle.
Three independent channels (three relays) control the connected appliances. Settings are entered in real time, with a maximum of 60 settings. Each programmed switching repeats every week and is defined by the time of operation, the day of the week and the channel number. The display shows the current time, also at temperatures down to minus 20 °C, and the programme stays in memory when the supply is switched off.
The supply is universal and comes in two versions, AC/DC 24-42 and AC/DC 110-240, at 50 Hz. Power consumption is not more than 5 VA (5 W). Clock error is not more than ±4 s per day, and the clock reserve is not less than 150 h.
The output is 3 changeover contacts. Continuous contact current is 8 A and the maximum switched power on a resistive load is 2000 W (AC1 at 8 A and 250 V). Operating temperature is minus 20 to plus 55 °C. The timer is IP40, the terminal block IP10, and the mass is not more than 0.3 kg.
Technical specifications
| Control channels | 3 |
|---|---|
| Maximum number of settings | 60 |
| Programme cycle | daily, weekly |
| Rated supply voltage | AC/DC 24-42; AC/DC 110-240 |
| Frequency | 50 Hz |
| Power consumption | not more than 5 VA (5 W) |
| Clock error per day | not more than ±4 s |
| Clock reserve | not less than 150 h |
| Relay contacts | 3 changeover |
| Continuous contact current | 8 A |
| Maximum switched power, resistive load | 2000 W (AC1 at 8 A and 250 V) |
| Operating temperature | from minus 20 to plus 55 °C |
| Protection degree, timer / terminal block | IP40 / IP10 |
| Mass | not more than 0.3 kg |
How it compares with similar models
| Parameter | РВЦ-03-2 weekly and daily cycle timer, 3 channels, 60 settings | ВЛ-50 time relay for railway rolling stock, 2–200 s settings, 27–110 V DC supply | БРП-01 isolation and noise suppression unit, 60 – 220 V 50 Hz, up to 0.2 A | РЗЛ-01.01 microprocessor protection and automation relay for 6-35 kV networks |
|---|---|---|---|---|
| Power consumption | not more than 5 VA (5 W) | 5 W max. | — | not more than 5 VA + 0,4 VA per energised discrete output |
| Continuous contact current | 8 A | 4 A max. | — | 8 A |
Request a price and lead time
РВЦ-03-2 weekly and daily cycle timer, 3 channels, 60 settings. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
How many channels and settings does the РВЦ-03-2 have?
Three independent channels and up to 60 settings.
How long does the clock keep running without supply?
The clock reserve is not less than 150 h.
What load can the contacts carry?
A continuous current of 8 A and a resistive load of up to 2000 W (AC1 at 8 A and 250 V).
Similar equipment from other manufacturers