International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

РЕП-20 electromagnetic intermediate relay with 8 contacts, 6 A

The РЕП-20 is an electromagnetic intermediate relay with eight contacts for switching loads in control circuits of AC drives up to 380 V 50 Hz or 440 V 60 Hz and DC drives up to 220 V. Six contact arrangements and many coil voltages are offered.

Switched circuits
AC up to 380 V 50 Hz, 440 V 60 Hz; DC up to 220 V
Rated contact current
6 A
Rated contact voltage
DC 12-220 V; AC 12-440 V
Minimum current at 12 V
0,01 A

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

РЕП-20 relays switch loads in control, protection and automation circuits, including the control circuits of electric drives: AC up to 380 V at 50 Hz, AC up to 440 V at 60 Hz and DC up to 220 V. The relay has eight contacts and comes in many versions that differ in rated coil voltage.

The contact arrangement is set by the type code: 80 (eight normally open contacts), 62 (six normally open and two normally closed), 44 (four and four), 42 (four normally open and two normally closed), 24 (two normally open and four normally closed) and 22 (two and two). The rated contact current is 6 A, with switched voltage of 12-220 V DC and 12-440 V AC; the minimum current at 12 V is 0,01 A.

Coils are available for DC at 12, 15, 24, 27, 48, 60, 110 and 220 V, for AC at 50 Hz from 12 to 415 V and for AC at 60 Hz from 12 to 440 V. The permitted supply voltage change is 0,85 - 1,05 Unom. Coil consumption is 4 W on DC and 7 VA on AC, and the own turn-on time is 0,03 s. Mechanical endurance is 20x106 cycles on AC and 30x106 on DC, and the insulation test voltage is 2500 V.

The relay operates at an air temperature from minus 50 to plus 55 °C and a relative humidity of not more than 98% at +35 °C. The environment is industrial, free of dust in concentrations that disturb relay operation; the mounting position is arbitrary. The relays conform to ТУ16-92 ИЕУВ.647155.002 ТУ.

The type designation encodes the contact group, the method of connecting external conductors, the presence of an operation indicator, the current type and the rated voltage. The relay is mounted on a detachable contact socket, screwed to a panel or soldered in.

Technical specifications

Switched circuitsAC up to 380 V 50 Hz, 440 V 60 Hz; DC up to 220 V
Rated contact current6 A
Rated contact voltageDC 12-220 V; AC 12-440 V
Minimum current at 12 V0,01 A
Contact group configurations80, 62, 44, 42, 24, 22
Coil voltage, DC12, 15, 24, 27, 48, 60, 110, 220 V
Coil voltage, AC 50 Hz12, 24, 40, 110, 127, 220, 230, 240, 380, 400, 415 V
Coil voltage, AC 60 Hz12, 24, 40, 110, 220, 230, 240, 380, 440 V
Permitted supply voltage change0,85 - 1,05 Unom
Power consumption4 W (DC), 7 VA (AC)
Own turn-on time0,03 s
Insulation test voltage2500 V
Mechanical endurance20x106 (AC), 30x106 (DC) cycles
Air temperaturefrom minus 50 to plus 55 °C
Relative humiditynot more than 98% at +35 °C
Technical specificationТУ16-92 ИЕУВ.647155.002 ТУ

Part numbers

Show all part numbers (6)

РЕП-20-80, РЕП-20-62, РЕП-20-44, РЕП-20-42, РЕП-20-24, РЕП-20-22

How it compares with similar models

ParameterРЕП-20 electromagnetic intermediate relay with 8 contacts, 6 AПЕ45А, ПЕ45А-1 electromagnetic intermediate relay with off-delay of 0,05 - 3,0 sPE41, PE41-M fast intermediate relay, 24-230 V DC and 24-400 V ACПЕ46, ПЕ46-1 two-position electromagnetic intermediate relay for 24-230 V DC and 24-400 V AC
Insulation test voltage2500 V—2500 V2500 V between independent circuits and case; 1000 V between open contacts; 550 V between coils
Mechanical endurance20x106 (AC), 30x106 (DC) cyclesnot less than 500000 cycles—100000 cycles

European equivalents

Auxiliary, bistable and contactor relays for substations

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

РЕП-20 electromagnetic intermediate relay with 8 contacts, 6 A. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which contact arrangements does the РЕП-20 come in?

The types are 80, 62, 44, 42, 24 and 22; the РЕП-20-80 has eight normally open contacts and the РЕП-20-44 has four normally open and four normally closed.

What loads can the contacts switch?

The rated contact current is 6 A, at 12-220 V DC and 12-440 V AC; the minimum current at 12 V is 0,01 A.

How is the РЕП-20 mounted?

It fits a detachable contact socket, can be screwed to a panel or soldered in, and the mounting position is arbitrary.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides