РЕП-20 electromagnetic intermediate relay with 8 contacts, 6 A
The РЕП-20 is an electromagnetic intermediate relay with eight contacts for switching loads in control circuits of AC drives up to 380 V 50 Hz or 440 V 60 Hz and DC drives up to 220 V. Six contact arrangements and many coil voltages are offered.
- Switched circuits
- AC up to 380 V 50 Hz, 440 V 60 Hz; DC up to 220 V
- Rated contact current
- 6 A
- Rated contact voltage
- DC 12-220 V; AC 12-440 V
- Minimum current at 12 V
- 0,01 A
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
РЕП-20 relays switch loads in control, protection and automation circuits, including the control circuits of electric drives: AC up to 380 V at 50 Hz, AC up to 440 V at 60 Hz and DC up to 220 V. The relay has eight contacts and comes in many versions that differ in rated coil voltage.
The contact arrangement is set by the type code: 80 (eight normally open contacts), 62 (six normally open and two normally closed), 44 (four and four), 42 (four normally open and two normally closed), 24 (two normally open and four normally closed) and 22 (two and two). The rated contact current is 6 A, with switched voltage of 12-220 V DC and 12-440 V AC; the minimum current at 12 V is 0,01 A.
Coils are available for DC at 12, 15, 24, 27, 48, 60, 110 and 220 V, for AC at 50 Hz from 12 to 415 V and for AC at 60 Hz from 12 to 440 V. The permitted supply voltage change is 0,85 - 1,05 Unom. Coil consumption is 4 W on DC and 7 VA on AC, and the own turn-on time is 0,03 s. Mechanical endurance is 20x106 cycles on AC and 30x106 on DC, and the insulation test voltage is 2500 V.
The relay operates at an air temperature from minus 50 to plus 55 °C and a relative humidity of not more than 98% at +35 °C. The environment is industrial, free of dust in concentrations that disturb relay operation; the mounting position is arbitrary. The relays conform to ТУ16-92 ИЕУВ.647155.002 ТУ.
The type designation encodes the contact group, the method of connecting external conductors, the presence of an operation indicator, the current type and the rated voltage. The relay is mounted on a detachable contact socket, screwed to a panel or soldered in.
Technical specifications
| Switched circuits | AC up to 380 V 50 Hz, 440 V 60 Hz; DC up to 220 V |
|---|---|
| Rated contact current | 6 A |
| Rated contact voltage | DC 12-220 V; AC 12-440 V |
| Minimum current at 12 V | 0,01 A |
| Contact group configurations | 80, 62, 44, 42, 24, 22 |
| Coil voltage, DC | 12, 15, 24, 27, 48, 60, 110, 220 V |
| Coil voltage, AC 50 Hz | 12, 24, 40, 110, 127, 220, 230, 240, 380, 400, 415 V |
| Coil voltage, AC 60 Hz | 12, 24, 40, 110, 220, 230, 240, 380, 440 V |
| Permitted supply voltage change | 0,85 - 1,05 Unom |
| Power consumption | 4 W (DC), 7 VA (AC) |
| Own turn-on time | 0,03 s |
| Insulation test voltage | 2500 V |
| Mechanical endurance | 20x106 (AC), 30x106 (DC) cycles |
| Air temperature | from minus 50 to plus 55 °C |
| Relative humidity | not more than 98% at +35 °C |
| Technical specification | ТУ16-92 ИЕУВ.647155.002 ТУ |
Part numbers
Show all part numbers (6)
РЕП-20-80, РЕП-20-62, РЕП-20-44, РЕП-20-42, РЕП-20-24, РЕП-20-22
How it compares with similar models
| Parameter | РЕП-20 electromagnetic intermediate relay with 8 contacts, 6 A | ПЕ45А, ПЕ45А-1 electromagnetic intermediate relay with off-delay of 0,05 - 3,0 s | PE41, PE41-M fast intermediate relay, 24-230 V DC and 24-400 V AC | ПЕ46, ПЕ46-1 two-position electromagnetic intermediate relay for 24-230 V DC and 24-400 V AC |
|---|---|---|---|---|
| Insulation test voltage | 2500 V | — | 2500 V | 2500 V between independent circuits and case; 1000 V between open contacts; 550 V between coils |
| Mechanical endurance | 20x106 (AC), 30x106 (DC) cycles | not less than 500000 cycles | — | 100000 cycles |
European equivalents
Auxiliary, bistable and contactor relays for substations
selected by purpose and main parameters, please confirm with our manager
Request a price and lead time
РЕП-20 electromagnetic intermediate relay with 8 contacts, 6 A. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which contact arrangements does the РЕП-20 come in?
The types are 80, 62, 44, 42, 24 and 22; the РЕП-20-80 has eight normally open contacts and the РЕП-20-44 has four normally open and four normally closed.