ПЕ45Н electromagnetic intermediate relay with off-delay of 0,05 - 1,0 s and neutral relay

The ПЕ45Н is an electromagnetic intermediate relay for DC and AC, built with a neutral relay, with an off-delay of 0,05 to 1,0 s. Turn-on time is not more than 0,05 s, and it switches 24-230 V DC and 24-400 V AC.

Type
off-delay, with neutral relay
Switched circuits
DC 24 - 230 V; AC 24 - 400 V, 50 and 60 Hz
Turn-on time
not more than 0,05 s
Drop-out time (delay)
from 0,05 to 1,0 s

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The ПЕ45Н has a release delay of 0,05 to 1,0 s and a turn-on time of not more than 0,05 s. It works on DC and AC and is built with a neutral relay. It is used in protection, control and automation circuits of power equipment to switch DC loads rated 24 to 230 V and AC loads rated 24 to 400 V at 50 and 60 Hz.

On DC the pick-up voltage is 0,6-0,7 Unom and the drop-out voltage is 0,3 Unom. The relay carries up to 6 contact groups, with a minimum contact current of 0,02 A at 24 V and 0,01 A at 110 V and above. Coils draw not more than 6 W on DC and 10 VA on AC. Mechanical endurance is 100000 cycles and switching endurance is 50000 cycles.

The insulation test voltage is 2500 V between all electrically independent circuits and the case and between independent circuits, 1000 V between the open contacts of each group and 550 V between coils. The insulation resistance of a dry, clean relay is not less than 20 MOhm cold and 6 MOhm heated.

The relays are made in У3 and Т3 versions for ambient temperatures from minus 40 to plus 55 °C. Vibration is tolerated up to 15 Hz at 3g and from 15 to 100 Hz at 1g. Protection is IP40 for the relay and IP10 for screw terminals to ГОСТ 14254-96. Wire cross-section is 0,12‑1,5 mm² for soldering and 0,75‑2,5 mm² for screw terminals. DIN rail mounting needs an additional module.

Technical specifications

Typeoff-delay, with neutral relay
Switched circuitsDC 24 - 230 V; AC 24 - 400 V, 50 and 60 Hz
Turn-on timenot more than 0,05 s
Drop-out time (delay)from 0,05 to 1,0 s
Pick-up voltage (DC)0,6-0,7 Unom
Drop-out voltage (DC)0,3 Unom
Minimum contact current0,02 A at 24 V; 0,01 A at 110 V and above
Coil power consumptionDC not more than 6 W; AC not more than 10 VA
Insulation test voltage2500 V between independent circuits and case; 1000 V between open contacts; 550 V between coils
Insulation resistance20 MOhm (cold), 6 MOhm (heated)
Protection degreeIP40 (relay), IP10 (screw terminals)
Ambient temperaturefrom minus 40 to plus 55 °C
Vibrationup to 15 Hz at 3g, 15 to 100 Hz at 1g
Wire cross-sectionsoldering 0,12‑1,5 mm²; screw 0,75‑2,5 mm²
Number of contactsup to 6 groups
Mechanical endurance100000 cycles
Switching endurance50000 cycles

How it compares with similar models

ParameterПЕ45Н electromagnetic intermediate relay with off-delay of 0,05 - 1,0 s and neutral relayПЕ45 electromagnetic intermediate relay with off-delay of 0,05 - 0,5 s and 0,4 - 2,5 sПЕ44, ПЕ44-М electromagnetic intermediate relay with on-delay of 0,05 - 0,253 sПЕ46, ПЕ46-1 two-position electromagnetic intermediate relay for 24-230 V DC and 24-400 V AC
Typeoff-delay, with neutral relayoff-delay, with bistable relayon-delay, 2 or 3 holding current windingstwo-position, DC and AC
Turn-on timenot more than 0,05 snot more than 0,05 s—not more than 0,03 s
Number of contactsup to 6 groupsup to 6 groupsup to 6 groupsup to 6 groups, normally open and normally closed

European equivalents

Auxiliary, bistable and contactor relays for substations

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

ПЕ45Н electromagnetic intermediate relay with off-delay of 0,05 - 1,0 s and neutral relay. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What release delay does the ПЕ45Н offer?

The delay is 0,05 to 1,0 s, and the turn-on time is not more than 0,05 s.

What are the pick-up and drop-out voltages on DC?

Pick-up is at 0,6-0,7 Unom and drop-out is at 0,3 Unom.

How many contact groups and what endurance?

Up to 6 contact groups, with a mechanical endurance of 100000 cycles and a switching endurance of 50000 cycles.