ПЕ46, ПЕ46-1 two-position electromagnetic intermediate relay for 24-230 V DC and 24-400 V AC
The ПЕ46 and ПЕ46-1 are two-position electromagnetic intermediate relays for DC and AC with a turn-on time of not more than 0,03 s. They switch circuits of 24-230 V DC and 24-400 V AC at 50 and 60 Hz, with up to 6 contact groups.
- Type
- two-position, DC and AC
- Switched circuits
- DC 24 - 230 V; AC 24 - 400 V, 50 and 60 Hz
- Turn-on time
- not more than 0,03 s
- Minimum contact current
- 0,02 A at 24 V; 0,01 A at 110 V and above
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The ПЕ46 and ПЕ46-1 are two-position intermediate relays for DC and AC, with a turn-on time of not more than 0,03 s. They are used in protection, control and automation circuits of power equipment to switch electrical loads in DC circuits rated 24 to 230 V and AC circuits rated 24 to 400 V at 50 and 60 Hz.
The relay carries up to 6 contact groups, normally open and normally closed. The minimum contact current is 0,02 A at 24 V and 0,01 A at 110 V and above. Coil consumption is not more than 6 W on DC and 10 VA on AC. Mechanical endurance is 100000 operating cycles and switching endurance is 50000 cycles.
Insulation withstands a test voltage of 2500 V between all electrically independent circuits and the case and between independent circuits, 1000 V between the open contacts of each group and 550 V between the energising and holding coils. The insulation resistance of a dry, clean relay is not less than 20 MOhm cold and 6 MOhm heated.
The relays are made in У3 and Т3 versions for ambient temperatures from minus 40 to plus 55 °C. Vibration is tolerated up to 15 Hz at 3g and from 15 to 100 Hz at 1g. Protection is IP40 for the relay and IP10 for screw terminals to ГОСТ 14254-96.
Connection is at the front or rear, and mounting is on a DIN rail or by screw; the DIN rail needs an additional module. Wire cross-section is 0,12‑1,5 mm² for soldering and 0,75‑2,5 mm² for screw terminals.
Technical specifications
| Type | two-position, DC and AC |
|---|---|
| Switched circuits | DC 24 - 230 V; AC 24 - 400 V, 50 and 60 Hz |
| Turn-on time | not more than 0,03 s |
| Minimum contact current | 0,02 A at 24 V; 0,01 A at 110 V and above |
| Coil power consumption | DC not more than 6 W; AC not more than 10 VA |
| Insulation test voltage | 2500 V between independent circuits and case; 1000 V between open contacts; 550 V between coils |
| Insulation resistance | 20 MOhm (cold), 6 MOhm (heated) |
| Protection degree | IP40 (relay), IP10 (screw terminals) |
| Ambient temperature | from minus 40 to plus 55 °C |
| Vibration | up to 15 Hz at 3g, 15 to 100 Hz at 1g |
| Wire cross-section | soldering 0,12‑1,5 mm²; screw 0,75‑2,5 mm² |
| Number of contacts | up to 6 groups, normally open and normally closed |
| Mechanical endurance | 100000 cycles |
| Switching endurance | 50000 cycles |
| Connection and mounting | front, rear; on DIN rail or by screw |
How it compares with similar models
| Parameter | ПЕ46, ПЕ46-1 two-position electromagnetic intermediate relay for 24-230 V DC and 24-400 V AC | ПЕ45Н electromagnetic intermediate relay with off-delay of 0,05 - 1,0 s and neutral relay | ПЕ45 electromagnetic intermediate relay with off-delay of 0,05 - 0,5 s and 0,4 - 2,5 s | ПЕ44, ПЕ44-М electromagnetic intermediate relay with on-delay of 0,05 - 0,253 s |
|---|---|---|---|---|
| Type | two-position, DC and AC | off-delay, with neutral relay | off-delay, with bistable relay | on-delay, 2 or 3 holding current windings |
| Turn-on time | not more than 0,03 s | not more than 0,05 s | not more than 0,05 s | — |
| Number of contacts | up to 6 groups, normally open and normally closed | up to 6 groups | up to 6 groups | up to 6 groups |
European equivalents
Auxiliary, bistable and contactor relays for substations
selected by purpose and main parameters, please confirm with our manager
Request a price and lead time
ПЕ46, ПЕ46-1 two-position electromagnetic intermediate relay for 24-230 V DC and 24-400 V AC. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which circuits do the ПЕ46 and ПЕ46-1 switch?
DC circuits from 24 to 230 V and AC circuits from 24 to 400 V at 50 and 60 Hz.
What are the turn-on time and endurance?
Turn-on time is not more than 0,03 s, mechanical endurance is 100000 cycles and switching endurance is 50000 cycles.
How is the relay mounted and which wire sizes fit?
It mounts on a DIN rail with an additional module or by screw; wires are 0,12‑1,5 mm² for soldering and 0,75‑2,5 mm² for screw terminals.