ПЕ44, ПЕ44-М electromagnetic intermediate relay with on-delay of 0,05 - 0,253 s
The ПЕ44 and ПЕ44-М are DC and AC intermediate relays with an on-delay of 0,05 to 0,253 s and two or three holding current windings. They switch 24-230 V DC and 24-400 V AC, with up to 6 contact groups.
- Type
- on-delay, 2 or 3 holding current windings
- Switched circuits
- DC 24 - 230 V; AC 24 - 400 V, 50 and 60 Hz
- Operate time on turn-on
- from 0,05 to 0,253 s
- Operate time of ПЕ44-20-50, -14, -41
- from 3,4 to 4,4 s
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The ПЕ44 and ПЕ44-М are on-delay relays for DC and AC with two or three holding current windings. Operate time on turn-on is 0,05 to 0,253 s; the versions ПЕ44-20-50, ПЕ44-20-14 and ПЕ44-20-41 operate in 3,4 to 4,4 s. The relays serve protection, control and automation circuits of power equipment, switching DC circuits of 24-230 V and AC circuits of 24-400 V at 50 and 60 Hz.
The ПЕ44 is the basic version and the ПЕ44-М carries a module in a transparent case. Two modules exist. The М3 gives relay status indication by a red LED at 100-230V AC and 110-220V DC, and the М4 adds surge protection with a varistor plus indication at 12-230V AC and 24-220V DC. Terminal polarity is А1+, А2-.
There are up to 6 contact groups. The minimum contact current is 0,02 A at 24 V and 0,01 A at 110 V and above. Coils draw not more than 6 W on DC and 10 VA on AC. Mechanical endurance is 100000 cycles and switching endurance is 50000 cycles.
The insulation test voltage is 2500 V between independent circuits and the case and between independent circuits, 1000 V between open contacts and 550 V between coils. Insulation resistance is not less than 20 MOhm cold and 6 MOhm heated. Protection is IP40 for the relay and IP10 for the terminals.
Versions У3 and Т3 cover ambient temperatures from minus 40 to plus 55 °C, with vibration up to 15 Hz at 3g and from 15 to 100 Hz at 1g.
Technical specifications
| Type | on-delay, 2 or 3 holding current windings |
|---|---|
| Switched circuits | DC 24 - 230 V; AC 24 - 400 V, 50 and 60 Hz |
| Operate time on turn-on | from 0,05 to 0,253 s |
| Operate time of ПЕ44-20-50, -14, -41 | from 3,4 to 4,4 s |
| Minimum contact current | 0,02 A at 24 V; 0,01 A at 110 V and above |
| Coil power consumption | DC not more than 6 W; AC not more than 10 VA |
| Insulation test voltage | 2500 V between independent circuits and case; 1000 V between open contacts; 550 V between coils |
| Insulation resistance | 20 MOhm (cold), 6 MOhm (heated) |
| Protection degree | IP40 (relay), IP10 (screw terminals) |
| Ambient temperature | from minus 40 to plus 55 °C |
| Vibration | up to 15 Hz at 3g, 15 to 100 Hz at 1g |
| Number of contacts | up to 6 groups |
| Mechanical endurance | 100000 cycles |
| Switching endurance | 50000 cycles |
| Module М3 | relay status indication (red LED), 100-230V AC, 110-220V DC, А1+, А2- |
| Module М4 | surge protection and status indication (varistor and red LED), 12-230V AC, 24-220V DC, А1+, А2- |
Part numbers
Show all part numbers (7)
ПЕ44, ПЕ44-М, ПЕ44-20-50, ПЕ44-20-14, ПЕ44-20-41, ПЕ44-20-ХХ-М3, ПЕ44-20-ХХ-М4
How it compares with similar models
| Parameter | ПЕ44, ПЕ44-М electromagnetic intermediate relay with on-delay of 0,05 - 0,253 s | ПЕ45Н electromagnetic intermediate relay with off-delay of 0,05 - 1,0 s and neutral relay | ПЕ45 electromagnetic intermediate relay with off-delay of 0,05 - 0,5 s and 0,4 - 2,5 s | ПЕ46, ПЕ46-1 two-position electromagnetic intermediate relay for 24-230 V DC and 24-400 V AC |
|---|---|---|---|---|
| Type | on-delay, 2 or 3 holding current windings | off-delay, with neutral relay | off-delay, with bistable relay | two-position, DC and AC |
| Number of contacts | up to 6 groups | up to 6 groups | up to 6 groups | up to 6 groups, normally open and normally closed |
European equivalents
Auxiliary, bistable and contactor relays for substations
selected by purpose and main parameters, please confirm with our manager
Request a price and lead time
ПЕ44, ПЕ44-М electromagnetic intermediate relay with on-delay of 0,05 - 0,253 s. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What on-delay does the ПЕ44 have?
Operate time is 0,05 to 0,253 s; the versions ПЕ44-20-50, ПЕ44-20-14 and ПЕ44-20-41 operate in 3,4 to 4,4 s.
How does the ПЕ44-М differ from the ПЕ44?
The ПЕ44-М carries a module in a transparent case; the М3 gives status indication and the М4 adds surge protection and indication.
Which circuits does the relay switch?
DC circuits of 24-230 V and AC circuits of 24-400 V at 50 and 60 Hz, with up to 6 contact groups.
Similar equipment from other manufacturers