International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

ПЕ44, ПЕ44-М electromagnetic intermediate relay with on-delay of 0,05 - 0,253 s

The ПЕ44 and ПЕ44-М are DC and AC intermediate relays with an on-delay of 0,05 to 0,253 s and two or three holding current windings. They switch 24-230 V DC and 24-400 V AC, with up to 6 contact groups.

Type
on-delay, 2 or 3 holding current windings
Switched circuits
DC 24 - 230 V; AC 24 - 400 V, 50 and 60 Hz
Operate time on turn-on
from 0,05 to 0,253 s
Operate time of ПЕ44-20-50, -14, -41
from 3,4 to 4,4 s

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The ПЕ44 and ПЕ44-М are on-delay relays for DC and AC with two or three holding current windings. Operate time on turn-on is 0,05 to 0,253 s; the versions ПЕ44-20-50, ПЕ44-20-14 and ПЕ44-20-41 operate in 3,4 to 4,4 s. The relays serve protection, control and automation circuits of power equipment, switching DC circuits of 24-230 V and AC circuits of 24-400 V at 50 and 60 Hz.

The ПЕ44 is the basic version and the ПЕ44-М carries a module in a transparent case. Two modules exist. The М3 gives relay status indication by a red LED at 100-230V AC and 110-220V DC, and the М4 adds surge protection with a varistor plus indication at 12-230V AC and 24-220V DC. Terminal polarity is А1+, А2-.

There are up to 6 contact groups. The minimum contact current is 0,02 A at 24 V and 0,01 A at 110 V and above. Coils draw not more than 6 W on DC and 10 VA on AC. Mechanical endurance is 100000 cycles and switching endurance is 50000 cycles.

The insulation test voltage is 2500 V between independent circuits and the case and between independent circuits, 1000 V between open contacts and 550 V between coils. Insulation resistance is not less than 20 MOhm cold and 6 MOhm heated. Protection is IP40 for the relay and IP10 for the terminals.

Versions У3 and Т3 cover ambient temperatures from minus 40 to plus 55 °C, with vibration up to 15 Hz at 3g and from 15 to 100 Hz at 1g.

Technical specifications

Typeon-delay, 2 or 3 holding current windings
Switched circuitsDC 24 - 230 V; AC 24 - 400 V, 50 and 60 Hz
Operate time on turn-onfrom 0,05 to 0,253 s
Operate time of ПЕ44-20-50, -14, -41from 3,4 to 4,4 s
Minimum contact current0,02 A at 24 V; 0,01 A at 110 V and above
Coil power consumptionDC not more than 6 W; AC not more than 10 VA
Insulation test voltage2500 V between independent circuits and case; 1000 V between open contacts; 550 V between coils
Insulation resistance20 MOhm (cold), 6 MOhm (heated)
Protection degreeIP40 (relay), IP10 (screw terminals)
Ambient temperaturefrom minus 40 to plus 55 °C
Vibrationup to 15 Hz at 3g, 15 to 100 Hz at 1g
Number of contactsup to 6 groups
Mechanical endurance100000 cycles
Switching endurance50000 cycles
Module М3relay status indication (red LED), 100-230V AC, 110-220V DC, А1+, А2-
Module М4surge protection and status indication (varistor and red LED), 12-230V AC, 24-220V DC, А1+, А2-

Part numbers

Show all part numbers (7)

ПЕ44, ПЕ44-М, ПЕ44-20-50, ПЕ44-20-14, ПЕ44-20-41, ПЕ44-20-ХХ-М3, ПЕ44-20-ХХ-М4

How it compares with similar models

ParameterПЕ44, ПЕ44-М electromagnetic intermediate relay with on-delay of 0,05 - 0,253 sПЕ45Н electromagnetic intermediate relay with off-delay of 0,05 - 1,0 s and neutral relayПЕ45 electromagnetic intermediate relay with off-delay of 0,05 - 0,5 s and 0,4 - 2,5 sПЕ46, ПЕ46-1 two-position electromagnetic intermediate relay for 24-230 V DC and 24-400 V AC
Typeon-delay, 2 or 3 holding current windingsoff-delay, with neutral relayoff-delay, with bistable relaytwo-position, DC and AC
Number of contactsup to 6 groupsup to 6 groupsup to 6 groupsup to 6 groups, normally open and normally closed

European equivalents

Auxiliary, bistable and contactor relays for substations

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

ПЕ44, ПЕ44-М electromagnetic intermediate relay with on-delay of 0,05 - 0,253 s. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What on-delay does the ПЕ44 have?

Operate time is 0,05 to 0,253 s; the versions ПЕ44-20-50, ПЕ44-20-14 and ПЕ44-20-41 operate in 3,4 to 4,4 s.

How does the ПЕ44-М differ from the ПЕ44?

The ПЕ44-М carries a module in a transparent case; the М3 gives status indication and the М4 adds surge protection and indication.

Which circuits does the relay switch?

DC circuits of 24-230 V and AC circuits of 24-400 V at 50 and 60 Hz, with up to 6 contact groups.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides