+ SCADA — power plant controller for solar, wind, hybrid plants and BESS (PPC PV / WIND / HYBRID / BESS)

PPC + SCADA is a power plant controller for utility-scale solar and wind plants, hybrid plants and BESS energy storage systems. It coordinates the inverters, wind turbines, batteries, capacitor and reactor banks and plant transformers, and implements the grid code requirements at the point of connection. The controller is supplied together with a SCADA according to ISA-101 and supports IEC 61850, IEC 60870-5-104, DNP3 and Modbus.

Versions
PPC PV, PPC WIND (primary/secondary), PPC HYBRID, PPC BESS
Modes at the point of connection
P (constant / frequency-dependent), Q (constant / voltage-dependent), PF (constant / P-dependent), U
Functions
compensation of shading / wind drop, losses and local loads, generation priority, control of capacitor / reactor banks and OLTC
Limiters
ANSI 24, ANSI 32, ANSI 27/59

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

A power plant controller is needed where many inverters or wind turbines must work on the grid as a single facility. According to the manufacturer's description, a PPC is mandatory at utility-scale renewable plants, that is, at facilities above 5 MW with a single owner. The controller coordinates generating and storage facilities, capacitor and reactor banks and plant transformers. Optionally it holds the permissible voltage level for the plant's own low- and medium-voltage loads.

There are four versions. PPC PV controls central or string solar inverters and other PPCs. PPC WIND coordinates wind turbines or other wind PPCs, including in a primary/secondary PPC topology when controllers from different manufacturers are already installed at the plant. PPC HYBRID combines different sources and storage into one cluster (solar + wind, hydro + floating PV, thermal or diesel generation + solar), limits export to the contracted power and relieves the grid by charging batteries. PPC BESS manages battery charge and discharge for price arbitrage and in modes that extend battery service life.

At the point of connection the controller regulates active power (constant or frequency-dependent), reactive power (constant or voltage-dependent), power factor (constant or dependent on active power) and voltage. If one module of the cluster under-delivers because of shading or a drop in wind, the PPC raises the output of the other modules. It compensates losses and local loads, sets priority for individual plants during curtailments, switches capacitor and reactor banks on and off, and controls the OLTC of the step-up transformer. Dynamic limiters for transformer overexcitation (ANSI 24), maximum power (ANSI 32), and minimum and maximum voltage (ANSI 27/59) keep the equipment from leaving its operating limits. The brochure also names applications such as black start, frequency and voltage regulation, transmission relief, peak shaving and energy arbitrage.

The operator interface and SCADA are built according to ISA-101. The SCADA works locally and remotely, and the HMI is intended for local control. Physical communication channels are Ethernet, single-mode or multimode fiber, and RS-485. Supported protocols are Modbus TCP/RTU, IEC 60870-5-101/104, IEC 61850, DNP3, OPC DA/UA, Profibus DP and EtherNet/IP, together with network functions VLAN (IEEE 802.1Q), QoS, RSTP (IEEE 802.1w) and MRP. The control cabinet is powered from 125 V DC, optionally from 100–240 V AC, can have a 24 V DC 5 A 7.2 Ah UPS, and is built to IP54 for installation under a canopy.

Technical specifications

VersionsPPC PV, PPC WIND (primary/secondary), PPC HYBRID, PPC BESS
Modes at the point of connectionP (constant / frequency-dependent), Q (constant / voltage-dependent), PF (constant / P-dependent), U
Functionscompensation of shading / wind drop, losses and local loads, generation priority, control of capacitor / reactor banks and OLTC
LimitersANSI 24, ANSI 32, ANSI 27/59
HMI/SCADAaccording to ISA-101
InterfacesEthernet, SM/MM fiber, RS-485
ProtocolsModbus TCP/RTU, IEC 60870-5-101/104, IEC 61850, DNP3, OPC DA/UA, Profibus DP, EtherNet/IP
NetworkVLAN 802.1Q, QoS, RSTP 802.1w, MRP
Cabinet power supply125 V DC / 100–240 V AC (option); UPS 24 V DC 5 A 7.2 Ah (option)
Cabinet protectionIP54 (under a canopy)

Request a price and lead time

+ SCADA — power plant controller for solar, wind, hybrid plants and BESS (PPC PV / WIND / HYBRID / BESS). We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which plants need a PPC controller?

According to the manufacturer's description, a PPC is mandatory at utility-scale renewable plants above 5 MW with a single owner. The PPC PV, PPC WIND, PPC HYBRID and PPC BESS versions cover solar and wind plants, hybrid clusters and storage.

What communication protocols does PPC + SCADA support?

Modbus TCP/RTU, IEC 60870-5-101/104, IEC 61850, DNP3, OPC DA/UA, Profibus DP and EtherNet/IP. Physical channels include Ethernet, SM/MM fiber and RS-485.

What power supply and protection does the controller cabinet have?

The cabinet is powered from 125 V DC or optionally from 100–240 V AC and can be fitted with a 24 V DC 5 A 7.2 Ah UPS. The IP54 degree of protection is intended for installation under a canopy.