
Noedra SCADA HMI, substation supervisory control and visualization system (Noedra Node)
Noedra SCADA HMI is a supervisory control, data acquisition and visualization system for substations. It is part of the Noedra Node suite of the Noedra digital platform. The system supports more than 300 protocol drivers and has 99.99 % availability with redundancy and no data loss.
- Functions
- process visualization, alarm management, trends, analytics, reports
- Protocols
- more than 300 drivers: IEC 61850, IEC 60870-5-104, DNP3, Modbus, OPC UA and legacy
- Cybersecurity
- IEC 62443, NERC CIP, NIS2; encryption, audit, role-based access
- Availability
- 99.99 %, redundancy with automatic switchover without data loss
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Noedra Node combines sensors, diagnostics, predictive analytics, protection, automation and control into one digital layer of the substation. The facility becomes "self-aware": it assesses its own condition and warns about risks. Alongside SCADA HMI, Node includes monitoring and diagnostics of transformers and switchgear, as well as engineering and integration of protection, automation and control (PAC) systems for traditional and digital substations under IEC 61850 with station bus and process bus.
SCADA HMI is aimed at substations with heterogeneous equipment, protocols and legacy devices, where traditional interfaces are overloaded with alarms and make integration difficult. The operator gets real-time process visualization, alarm management, trends, analytics and reports. The libraries contain special control and optimization functions, and there is a soft logic runtime (Soft PLC) under IEC 61131-3. For engineering there are automation wizards, ready templates and configuration tools, so commissioning takes less time.
More than 300 protocol drivers cover IEC 61850, IEC 60870-5-104, DNP3, Modbus, OPC UA and legacy protocols. Protection terminals, PLCs, meters and old devices are connected to the system. Cybersecurity is built into the architecture, with compliance with IEC 62443, NERC CIP and NIS2, encrypted communication, audit logs and role-based access control. Redundancy with automatic switchover maintains 99.99 % availability without data loss.
The architecture scales from small substations to enterprise networks and supports multi-project and distributed SCADA. Installation is possible on substation-, industrial- or office-grade hardware, in a virtual environment and in the cloud. PAC engineering within Node covers the complete protection, automation and control design of an AC substation, including the network part, hardware selection and process bus. For communication with control centers there are gateways and RTUs for IEC 104 and DNP3 telecontrol, protocol conversion and data concentration. The delivery covers hardware, software and engineering, mapping of signals to protection and control devices, commissioning, documentation and training.
The system is deployed at new and modernized substations of grid companies and industrial enterprises, including digital substations under IEC 61850.
Technical specifications
| Functions | process visualization, alarm management, trends, analytics, reports |
|---|---|
| Protocols | more than 300 drivers: IEC 61850, IEC 60870-5-104, DNP3, Modbus, OPC UA and legacy |
| Cybersecurity | IEC 62443, NERC CIP, NIS2; encryption, audit, role-based access |
| Availability | 99.99 %, redundancy with automatic switchover without data loss |
| Deployment | on premises, virtualization, cloud; substation-, industrial- or office-grade hardware |
| Tools | automation wizards, templates, configuration tools |
Request a price and lead time
Noedra SCADA HMI, substation supervisory control and visualization system (Noedra Node). We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Customs codes
| UKTZED (Ukraine) | 8537 10 91 00 8537 10 98 00 |
|---|---|
| HS, 6 digits | 8537 10 |
| CN (EU) | 8537 10 91 8537 10 98 |
| HTSUS (USA) | 8537 10 91 70 |
| China customs tariff | 8537 10 90 90 |
Codes are for reference: the final code is determined at declaration for the specific model.
Questions and answers
Which protocols does Noedra SCADA HMI support?
More than 300 drivers, among them IEC 61850, IEC 60870-5-104, DNP3, Modbus and OPC UA. Legacy protocols are also supported.
What availability does the Noedra SCADA HMI system have?
Redundancy with automatic switchover provides 99.99 % availability without data loss.
Which cybersecurity standards does Noedra SCADA HMI comply with?
The system complies with IEC 62443, NERC CIP and NIS2. Communication is encrypted, audit logs are kept and access is separated by roles.
Similar equipment from other manufacturers






