International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

MR-F-DI4 Modbus RTU module with 4 digital inputs, 24 V AC/DC

The MR-F-DI4 has 4 digital inputs for potential-free contacts or voltage signals. A Modbus master reads their states through standard registers over RS-485. Supply is 24 V AC/DC and it mounts on a TH35 rail.

Digital inputs
4
Voltage input
30 V AC/DC
High signal detection
> 7 V AC/DC
Operating voltage
24 V AC/DC +/- 10 % (SELV)

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Decentralised switching and scanning tasks are what the MR-F-DI4 is built for. It detects the state of potential-free contacts, for example limit switches on vent valves or auxiliary contacts of power contactors. The inputs can be driven by potential-free switches or contacts, or used as voltage inputs. A Modbus master, for example a COMTRAXX device, scans them through standard registers.

There are 4 digital inputs. The input voltage is up to 30 V AC/DC and a high signal is detected above 7 V AC/DC. The module needs 24 V AC/DC ±10 % (SELV) and draws up to 50 mA AC or 20 mA DC. It has polarity reversal protection for DC operation and protection against interchanged supply and bus connections.

The RS-485 interface runs Modbus RTU on a two-wire bus with potential equalisation, in bus or line topology, terminated with 120 Ω. Address (00 to 99), bit rate and parity are set with 2 rotary switches on the front or by software. The rate ranges from 1200 to 115200 Bd with 19200 Bd as the default. Parity defaults to Even (Odd and None are also available), and stop bits are 1 by default or 2.

The housing measures 35 mm x 69.3 mm x 60 mm, weighs 95 g and clips onto a TH35 rail to IEC 60715 in electrical distribution cabinets, in any position. Terminals are push-in spring clamps, and green, red and yellow LEDs show the status.

Up to 15 Modbus modules may sit side by side without a gap, or up to 2 A total consumption per supply connection. Operating temperature is -5 °C…55 °C and storage temperature is -20 °C…70 °C. Relative humidity is up to 85 % non-condensing, with IP40 for the housing and IP20 for the terminals.

Technical specifications

Digital inputs4
Voltage input30 V AC/DC
High signal detection> 7 V AC/DC
Operating voltage24 V AC/DC +/- 10 % (SELV)
Power consumption AC (max.)50 mA
Power consumption DC (max.)20 mA
ProtocolModbus RTU, RS-485
Address range00 - 99
Transmission ratemin. 1200 Bit/s (Bd) - max. 115200 Bit/s (Bd)
Transmission rate default setting19200 Bit/s (Bd)
Dimensions (W x H x D)35 mm x 69.3 mm x 60 mm
Weight95 g
Protection category housing/terminal blocksIP40/IP20
Operating temperature-5 °C - 55 °C
Storage temperature-20 °C - 70 °C

Part numbers

Show all part numbers (2)

BF25510020, 110834131970

How it compares with similar models

ParameterMR-F-DI4 Modbus RTU module with 4 digital inputs, 24 V AC/DCMR-F-DOA4 Modbus RTU module with 4 relay outputs, 5 A per relayDI-1DL RS-485 interface repeater for BMS bus and Modbus RTUУСДМ-01 discrete data collection unit, 16 inputs, 8 relays, MODBUS RTU
Weight95 g95 gapprox. 90 g—
Operating temperature-5 °C - 55 °C-5 °C - 55 °C0…+70 °C—

Request a price and lead time

MR-F-DI4 Modbus RTU module with 4 digital inputs, 24 V AC/DC. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What signals can be connected to the MR-F-DI4 inputs?

Potential-free contacts or voltages up to 30 V AC/DC. A high signal is detected above 7 V AC/DC.

How are the address and communication settings made?

With 2 rotary switches on the front or by software. The address is 00 to 99 and the bit rate is 1200 to 115200 Bd, defaulting to 19200 Bd.

What supply does the module need?

24 V AC/DC ±10 % (SELV), drawing up to 50 mA AC or 20 mA DC. Up to 15 modules can be mounted side by side.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides