International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

ISOSCAN® EDS441 insulation fault locator for IT systems, 12 channels

Automatic fault locator for unearthed AC, three-phase and DC IT systems. It works with an ISOMETER® or a PGH test current generator and offers 12 measuring channels, an RS-485 interface and AC/DC 24…240 V supply. The response value is 0.2…1 mA.

Supply voltage
AC/DC 24…240 V
Response value (IΔL)
0.2…1 mA
Response value (IΔn)
100 mA…1 A
AC residual current display
50/60 Hz, 100 mA…2 A

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The ISOSCAN® EDS441 locates insulation faults automatically in unearthed AC, three-phase and DC IT systems. It operates together with an ISOMETER® or with a PGH test current generator. Typical uses are main and control circuits in industrial plants, diode-decoupled DC IT systems in power plants and systems for medical locations.

The device has 12 measuring channels, each connected to a measuring current transformer, and 12 relay channels are available as an option. The response value for fault location is 0.2…1 mA, and AC residual current at 50/60 Hz can be displayed from 100 mA to 2 A. With an active PGH generator, systems of AC 0…1000 V and DC 0…1500 V can be monitored, depending on the PGH type. Responsiveness depends on the system type, voltage, frequency, leakage capacitance and test current.

The versions are distinguished as follows. EDS441-S-1 is the standard version without current transformer connection monitoring, EDS441-L-4 adds that monitoring and EDS441-LAB-4 adds it together with the LAB procedure. Versions marked W are wall-mounted; the others mount on a DIN rail. The L versions carry channel LEDs.

Data leave the device over RS-485 using the BS bus or Modbus RTU. Supply is AC/DC 24…240 V, the frequency range is 50…400 Hz and the operating temperature is -25…+55 °C. Degree of protection is IP40 for the enclosure and IP20 for the terminals. Rated insulation voltage is AC 300 V and rated impulse voltage 4 kV. The unit weighs up to 450 g and measures 2.8″ x 3.6″ x 2.5″.

The design follows IEC 60664-1, IEC 61010-1, DIN VDE 0100-410 and IEC 60364-4-41, and the device is listed as a UL508 open type device. Climatic classes under IEC 60721-3-3 are 3K5 in use, 2K5 in transport and 1K5 in storage.

Technical specifications

Supply voltageAC/DC 24…240 V
Response value (IΔL)0.2…1 mA
Response value (IΔn)100 mA…1 A
AC residual current display50/60 Hz, 100 mA…2 A
Frequency range50…400 Hz
Systems with active PGH generatorAC 0…1000 V; DC 0…1500 V
Measuring channels12 (optional 12 relay channels)
InterfacesRS-485, BS bus protocol, Modbus RTU
Operating temperature-25…+55 °C
Degree of protectionIP40 (internal); IP20 (terminals)
Rated insulation voltageAC 300 V
Rated impulse voltage4 kV
Dimensions2.8″ x 3.6″ x 2.5″
Weight≤ 450 g

Part numbers

Show all part numbers (6)

B91080204, B91080204W, B91080205, B91080205W, B91080207, B91080207W

How it compares with similar models

ParameterISOSCAN® EDS441 insulation fault locator for IT systems, 12 channelsISOSCAN® EDS551 insulation fault locator for medical IT systems, 4 or 6 channelsISOSCAN® EDS440 insulation fault locator for IT systems, 12 channelsLINETRAXX® CEP410R-2 residual current monitor for the central earthing point
Supply voltageAC/DC 24…240 VDC 24 VDC 24 V; AC/DC 24…240 VDC 24 V; AC/DC 100…240 V
Measuring channels12 (optional 12 relay channels)4 or 612—
InterfacesRS-485, BS bus protocol, Modbus RTURS-485, NFC—RS-485 (Modbus RTU), NFC
Operating temperature-25…+55 °C−25…55 °C—-25…+55 °C
Dimensions2.8″ x 3.6″ x 2.5″245 × 38 × 40 (mm)—109 x 48.5 x 64 mm
Weight≤ 450 g290 g—≤ 100 g

Request a price and lead time

ISOSCAN® EDS441 insulation fault locator for IT systems, 12 channels. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How many channels does the EDS441 have and what is its response value?

It has 12 measuring channels, with 12 relay channels as an option. The response value for fault location is 0.2…1 mA.

How do the S, L and LAB versions differ?

EDS441-S-1 has no current transformer connection monitoring, EDS441-L-4 has it, and EDS441-LAB-4 has it plus the LAB procedure. The letter W marks the wall-mount version.

Which systems and voltages can be covered with a PGH generator?

With an active PGH, systems of AC 0…1000 V and DC 0…1500 V can be monitored, depending on the PGH type. The device works in unearthed AC, three-phase and DC IT systems.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides