ISOSCAN® EDS151 insulation fault locator, 6 channels, 0.5 mA sensitivity

The ISOSCAN® EDS151 pinpoints the circuit with an insulation fault in AC, AC/DC and DC IT systems, medical locations included. It has 6 measuring channels with current transformers, a response value of 0.5 mA and an RS-485 interface running the BMS protocol.

Supply voltage Us
AC 17…24 V, DC 14…28 V
Nominal system voltage Un
AC 20…265 V, DC 20…308 V
Rated frequency fn
42…460 Hz
Number of measuring channels
6 (up to 528 via BMS)

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The ISOSCAN® EDS151 localises insulation faults in AC, AC/DC and DC IT systems. It is meant for medical locations and control circuits, and it also serves DC main circuits in industrial plants, power stations and ships.

The locator does not begin the search on its own. The locating current comes from an ISOMETER® isoMED427P, an ATICS® transfer switching device or a PGH474 locating current injector, and any of these starts the search.

Once started, the EDS151 scans measuring channels 1…6. When a channel exceeds the response value of 0.5 mA, its alarm LED lights and the address and channel number go out over the BMS interface. The faulty circuit appears on an alarm and test combination or on a BMS master with a display. Several EDS151 units start at the same time.

Each unit carries 6 measuring channels with measuring current transformers. Up to 88 units share one RS-485 bus with the BMS protocol, giving up to 528 channels (88 x 6) in the monitored IT system. BMS addresses run from 3…90 and must not be assigned twice, because a duplicate disturbs the bus. A cyclical self test runs inside the device.

In an AC system the response time is up to 8 s according to IEC 61557-9. Nominal system voltage Un is AC 20…265 V or DC 20…308 V, at 42…460 Hz. The supply is AC 17…24 V or DC 14…28 V, and the AN410 (AC 90…264 V / DC 120…370 V, up to 6 EDS151) and AN450 (AC 230 V, up to 3 EDS151) power supply units can provide it. Operating temperature is −25…+55 °C and weight ≤ 340 g.

Technical specifications

Supply voltage UsAC 17…24 V, DC 14…28 V
Nominal system voltage UnAC 20…265 V, DC 20…308 V
Rated frequency fn42…460 Hz
Number of measuring channels6 (up to 528 via BMS)
Response value Ian0.5 mA
Measuring range EDS function0.5…2.5 mA
Response time in the AC system≤ 8 s
Interface/protocolRS-485 / BMS
BMS address range3…90
Operating temperature−25…+55 °C
Weight≤ 340 g
Rated insulation voltageAC 250 V
Rated impulse voltage/pollution degree6 kV/3

Part numbers

Show all part numbers (3)

B91080101, B924209, B924201

How it compares with similar models

ParameterISOSCAN® EDS151 insulation fault locator, 6 channels, 0.5 mA sensitivityISOSCAN® EDS150 insulation fault locator for main circuits, 6 channels, 5 mAISOSCAN® EDS551 insulation fault locator for medical IT systems, 4 or 6 channelsISOSCAN® EDS441 insulation fault locator for IT systems, 12 channels
Operating temperature−25…+55 °C—−25…55 °C-25…+55 °C
Weight≤ 340 g—290 g≤ 450 g

Request a price and lead time

ISOSCAN® EDS151 insulation fault locator, 6 channels, 0.5 mA sensitivity. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What starts the search and supplies the locating current?

An ISOMETER® isoMED427P, an ATICS® transfer switching device or a PGH474 injector starts the search and supplies the locating current. The EDS151 itself does not start it.

How many channels fit on one BMS bus?

Each EDS151 has 6 channels and up to 88 units share the bus, so up to 528 channels in total. BMS addresses run from 3…90, and a repeated address causes faults.

What are the response value and response time?

The response value is 0.5 mA, and the EDS function measures 0.5…2.5 mA. In an AC system the response time is up to 8 s per IEC 61557-9.