International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

ISOSCAN® EDS150 insulation fault locator for main circuits, 6 channels, 5 mA

The ISOSCAN® EDS150 localises insulation faults in the main circuits of AC, AC/DC and DC IT systems. It has 6 channels with integrated current transformers, a response sensitivity of 5 mA and up to 528 circuits on the BMS bus.

Number of measuring channels
6
Response sensitivity
5 mA
Response time in the AC system
max. 8 s
Max. devices on the BMS bus
88

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The ISOSCAN® EDS150 is an insulation fault locator for the main circuits of unearthed power supplies (IT systems), whether AC, AC/DC or DC. Among its uses are DC main circuits in industrial plants, power stations and ships.

The locating current needed for the search is supplied by an ISOMETER® IRDH575 or a PGH471 locating current injector, and either of them starts the search. After the start, the EDS150 scans all measuring channels 1…6 through its integrated measuring current transformers.

When the response value of 5 mA is exceeded in a channel, the associated alarm LED lights. The alarm message, with address and channel number, leaves through the BMS interface. The faulty circuit is shown on an alarm and test combination or on a BMS master with a display.

Up to 88 EDS150 units connect over the RS-485 interface with the BMS protocol, so up to 528 circuits can be monitored. The BMS address range is 3…90. The response time in an AC system is up to 8 s according to IEC 61557-9, and the device runs a cyclical self test.

The version with part number B91080103 is supplied with AC 17…24 V, 50…60 Hz or DC 14…28 V. External supply comes from the AN410 (AC 90…264 V / DC 120…370 V), AN450 (AC 230 V) or AN450-133 (AC 127 V) power supply units.

Technical specifications

Number of measuring channels6
Response sensitivity5 mA
Response time in the AC systemmax. 8 s
Max. devices on the BMS bus88
Max. circuits528
BMS address range3…90
Interface/protocolRS-485 / BMS
Supply voltageAC 17…24 V, 50…60 Hz / DC 14…28 V
Locating current sourceISOMETER® IRDH575 or PGH471

Part numbers

Show all part numbers (1)

B91080103

Request a price and lead time

ISOSCAN® EDS150 insulation fault locator for main circuits, 6 channels, 5 mA. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What supplies the locating current for the EDS150?

An ISOMETER® IRDH575 or a PGH471 locating current injector. Either of them also starts the search.

What is the response sensitivity of the EDS150?

The response value is 5 mA. In an AC system the response time is up to 8 s according to IEC 61557-9.

How many circuits can one EDS150 system monitor?

Up to 88 devices with 6 channels each share the BMS bus, which gives up to 528 circuits. BMS addresses run from 3…90.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides