International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

ISOSCAN® EDS30… portable insulation fault location system for IT and TN/TT systems

Portable set for tracing insulation faults in unearthed IT systems and measuring residual current in TN/TT systems. The kit has an EDS195P(M) evaluator, 20 mm and 52 mm measuring clamps and a locating current injector. Ten versions cover main circuits, control circuits and photovoltaic systems.

Nominal voltage EDS3090, 3090PG, 3090PG-13
AC 20…575 V, 42…460 Hz and DC 20…504 V
Nominal voltage EDS3096PG, 3096PG-13, 3096PV
AC 0…575 V, 42…460 Hz and DC 0…504 V
Nominal voltage EDS3091, 3091PG, 3091PG-13
AC 20…265 V, 42…460 Hz and DC 20…308 V
Nominal voltage EDS3092PG
AC 20…265 V / AC 20…575 V

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The ISOSCAN® EDS30… series is carried in an aluminium case and traces insulation faults in unearthed IT systems. In earthed TN/TT systems the same kit measures residual current.

A locating current injector of the PGH18… family feeds a test current of 1…25 mA (PGH185, PGH186) or 1/2.5 mA (PGH183) into the system. The operator closes a clamp around the conductor, and the EDS195P(M) evaluator reads the clamp signal to show which feeder carries the fault. The response value is 2…10 mA in main circuits and 0.2…1 mA in control circuits. Clamps of 20 mm and 52 mm are supplied, and a 115 mm clamp (PSA3165) is optional.

The versions differ by circuit type. EDS3090, EDS3090PG and EDS3090PG-13 are for main circuits at AC 20…575 V and DC 20…504 V. EDS3096PG and EDS3096PG-13 are for main circuits in IT systems and also work on de-energised systems; EDS3096PV is for photovoltaic systems. EDS3091, EDS3091PG and EDS3091PG-13 are for control circuits at AC 20…265 V and DC 20…308 V. EDS3092PG combines both. EDS3090 and EDS3091 have no integrated injector, while the PG models include PGH185, PGH186 or PGH183, and EDS3092PG includes PGH183 and PGH185.

Residual current is measured from 10 mA to 10 A. The kit is used in IT systems with or without installed EDS systems, in main circuits, control circuits and photovoltaic systems. Options include the AGE185 coupling device and the CTAF set.

PG models run from AC 230 V, 50…60 Hz and -13 models from AC 90…132 V, 50…60 Hz. Battery operation uses 3 × NiMH R6 AA cells, 1.2 V, at least 2000 mAh. The backlit LC display shows 3 × 16 characters. The case measures 430 × 340 × 155 mm and weighs up to 7000 g (EDS309…), 8500 g with the PSA3165 clamp and 9000 g (EDS3092).

The series follows DIN VDE 0100-410, DIN EN 61557-9 and DIN EN 61010-1, and carries the CE mark.

Technical specifications

Nominal voltage EDS3090, 3090PG, 3090PG-13AC 20…575 V, 42…460 Hz and DC 20…504 V
Nominal voltage EDS3096PG, 3096PG-13, 3096PVAC 0…575 V, 42…460 Hz and DC 0…504 V
Nominal voltage EDS3091, 3091PG, 3091PG-13AC 20…265 V, 42…460 Hz and DC 20…308 V
Nominal voltage EDS3092PGAC 20…265 V / AC 20…575 V
Supply voltageAC 230 V, 50…60 Hz (PG models); AC 90…132 V, 50…60 Hz (-13 models); battery 3 × NiMH R6 AA, 1.2 V, min. 2000 mAh
Response value of fault location2…10 mA (main circuits); 0.2…1 mA (control circuits)
Residual current measurement10 mA…10 A
Measuring clamps20 mm, 52 mm (supplied); 115 mm (optional PSA3165)
Test current1…25 mA (PGH185/186); 1/2.5 mA (PGH183)
DisplayBacklit LC display, 3 × 16 characters
Weight≤ 7000 g (EDS309...); ≤ 8500 g (with PSA3165); ≤ 9000 g (EDS3092)
Case dimensions430 × 340 × 155 mm

Part numbers

Show all part numbers (13)

B91082026, B91082021, B91082022, B91082025, B91082029, B91082027, B91082023, B91082024, B91082030, B91082031, B980852, B980305, B91082007

How it compares with similar models

ParameterISOSCAN® EDS30… portable insulation fault location system for IT and TN/TT systemsISOSCAN® EDS441 insulation fault locator for IT systems, 12 channelsISOSCAN® EDS440 insulation fault locator for IT systems, 12 channelsISOSCAN® EDS151 insulation fault locator, 6 channels, 0.5 mA sensitivity
Supply voltageAC 230 V, 50…60 Hz (PG models); AC 90…132 V, 50…60 Hz (-13 models); battery 3 × NiMH R6 AA, 1.2 V, min. 2000 mAhAC/DC 24…240 VDC 24 V; AC/DC 24…240 V—
Weight≤ 7000 g (EDS309...); ≤ 8500 g (with PSA3165); ≤ 9000 g (EDS3092)≤ 450 g—≤ 340 g

Request a price and lead time

ISOSCAN® EDS30… portable insulation fault location system for IT and TN/TT systems. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What separates EDS3090 from EDS3091?

EDS3090 is for main circuits at AC 20…575 V and DC 20…504 V, EDS3091 for control circuits at AC 20…265 V and DC 20…308 V. Neither has an integrated injector.

Which version suits de-energised and photovoltaic systems?

EDS3096PG and EDS3096PG-13 work on de-energised systems, and EDS3096PV is made for photovoltaic systems. All three include the PGH186 injector.

Which clamps come with the kit and what is the residual current range?

The kit includes 20 mm and 52 mm clamps; the 115 mm clamp (PSA3165) is ordered separately. Residual current is measured from 10 mA to 10 A.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides