HIPASE-T: digital hydro turbine governor with an oil pressure unit (HPU) up to 250 bar
HIPASE-T is a digital governor for Francis, Kaplan and Pelton turbines and pump-turbines that controls the turbine by speed and output. The set includes an oil pressure unit (HPU) with a design pressure of up to 250 bar. Suitable for new hydropower and pumped-storage plants and for replacing obsolete governors.
- Turbine types
- Francis, Kaplan, Pelton, pump-turbines
- Speed inputs
- up to 8, passive/active, from VT
- Analog inputs/outputs
- up to 24 / 28, -20...20 mA, -10...10 V
- Binary inputs/outputs
- up to 64
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The turbine governor consists of the HIPASE-T digital governor and an oil pressure unit (HPU) and controls the hydro turbine by speed and output. It holds a stable rotational speed at no load and in island operation, maintains setpoints in grid operation, takes part in primary frequency control, reacts quickly to load rejection and detects separation onto an isolated load. Switching between modes is bumpless. The modular application concept supports the requirements of different types and sizes of turbines. Special functions include flow calculation, adaptive optimization of the combinator relationship (CAM), a flushing function for Kaplan turbines and water hammer limitation.
The application board contains all types of inputs and outputs, including speed sensor interfaces and generator voltage measurement, analog position inputs and CT/VT inputs for power measurement. Analog outputs are configurable as current or voltage for controlling any servo valves. According to the technical data, there are up to 8 speed inputs, up to 24 analog inputs and 28 outputs (-20...20 mA, -10...10 V), up to 64 binary signals, a dead band of 0.02 %, a speed measurement range of 1.2-10 000 Hz with a resolution of 0.01 %, and compliance with IEC 61362 and IEC 60308. The governor can work stand-alone or as part of an existing system, and stability is confirmed by preliminary simulation.
All devices of the HIPASE family run on a single hardware platform and firmware and are programmed with one tool, HIPASE Engineering Tool (function block diagrams per IEC 61131). The housing has half or full 19'' width, and a built-in or separate 7'' color touch panel is available. The protocols IEC 61850 (MMS, GOOSE), IEC 60870-5-103/-104, Modbus TCP, OPC UA and FTP are supported. Cybersecurity is built on separation of the application and communication processors, a built-in firewall, encryption and regular updates.
The oil pressure unit is supplied complete, with a tank, pumps, distribution and main spool valves, filters, monitoring instruments and hydraulic accumulators. The design is modular, on standard industrial components, with a design pressure of up to 250 bar. For the main supply, self-regulating axial piston pumps are preferred, and fixed-delivery pumps (screw, gear) with control units are also possible. There are fail-safe main spool valves and special designs for old low-pressure systems. The turbine governor can be combined with the excitation controller in one HIPASE-ET device. Applications cover new hydropower and pumped-storage plants and the replacement of hydromechanical and obsolete electronic governors.
Technical specifications
| Turbine types | Francis, Kaplan, Pelton, pump-turbines |
|---|---|
| Speed inputs | up to 8, passive/active, from VT |
| Analog inputs/outputs | up to 24 / 28, -20...20 mA, -10...10 V |
| Binary inputs/outputs | up to 64 |
| Speed dead band | 0.02 % |
| Speed measurement range | 1.2-10 000 Hz, resolution 0.01 % |
| Standards | IEC 61362, IEC 60308 |
| HPU | modular, pressure up to 250 bar, axial piston pumps |
| Combination | HIPASE-ET (turbine governor + excitation in one device) |
Request a price and lead time
HIPASE-T: digital hydro turbine governor with an oil pressure unit (HPU) up to 250 bar. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What turbine types is HIPASE-T designed for?
For Francis, Kaplan and Pelton turbines and pump-turbines. Kaplan turbines have a flushing function, and all types have water hammer limitation.
How many inputs and outputs are there, and what standards apply?
Up to 8 speed inputs, up to 24 analog inputs and 28 outputs, up to 64 binary signals. Compliance with IEC 61362 and IEC 60308.
What pressure is the oil pressure unit designed for?
The modular HPU is designed for pressures up to 250 bar. The set includes a tank, pumps, spool valves, filters, monitoring instruments and hydraulic accumulators.