HighPROTEC MCA4 — protection of the point of connection of distributed generation to the MV grid

HighPROTEC MCA4 is a protection terminal for the point of connection of distributed generation to the medium voltage grid. Full compliance with VDE-AR-N 4110 is confirmed by a TÜV Nord certificate, and the ABS and Lloyd’s Register marine approvals extend its use to ships.

Purpose
connection of wind, solar and biogas plants to the grid; feeder protection, decoupling, backup generator protection
Compliance
VDE-AR-N 4110 (certified by TÜV Nord); IEC 60255-1:2009 (KEMA)
Marine approvals
ABS, Lloyd’s Register
CTs
1 A and 5 A, built-in test sockets

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The MCA4 from the HighPROTEC line connects distributed generation facilities to the grid: wind and solar power plants and biogas installations. The terminal protects the installation and makes sure that the connected generation complies with the grid rules. The independent institute TÜV Nord has certified the MCA4 as fully compliant with VDE-AR-N 4110. The quality of HighPROTEC devices has been confirmed at KEMA through all tests under IEC 60255-1:2009. The terminal is also used for feeder protection, grid decoupling and as backup generator protection.

The current inputs are designed for 1 A and 5 A CTs, and built-in test sockets are provided. The phase overcurrent protection has six stages, directional and non-directional (ANSI/IEC/51C/51V). The earth-fault protection has four stages, non-directional or directional with multi-polarisation, complemented by wattmetric protection. Two stages handle load unbalance. The voltage protection has six stages V<, V>, V<(t), and six more stages monitor voltage unbalance. The fourth voltage input works as VE> or for synchronism check. Frequency protection is set in six stages (f>, f<, df/dt, vector jump), and power protection also has six stages (P, Q, S, reverse power). There are separately two power factor stages and a limit on the maximum exported power.

The grid connection package is collected in a single menu. It includes non-selective unloading by active power direction, HVRT and FRT (LVRT) with adjustable profiles coordinated with auto-reclosing, Q-U protection, automatic reconnection, frequency protection, trip transfer and synchronism check. For power quality, THD protection is provided, together with recording of peak current and power values, average current and energy consumption.

The terminal runs on a dual-core processor. The Modbus, Profibus, DNP3.0, IEC 61850, IEC 60870-5-103 and IEC 60870-5-104 protocols have individual data point assignment, time is synchronised by SNTP and IRIG-B, and cybersecurity functions are included. Non-volatile recorders store waveforms of 120 s, 20 faults, 300 events and a trend of 4000 records. All protection, control and monitoring functions, the Smart view software and waveform analysis are included in the price under the all-inclusive concept. The MCA4 is used at the points of common coupling of wind and solar plants, at cogeneration and biogas installations, at industrial sites with their own generation, and on ships and offshore facilities.

Technical specifications

Purposeconnection of wind, solar and biogas plants to the grid; feeder protection, decoupling, backup generator protection
ComplianceVDE-AR-N 4110 (certified by TÜV Nord); IEC 60255-1:2009 (KEMA)
Marine approvalsABS, Lloyd’s Register
CTs1 A and 5 A, built-in test sockets
Overcurrent6 stages, directional/non-directional
Earth fault4 stages, multi-polarisation, wattmetric
Connection packageHVRT, LVRT, Q-U, automatic reconnection, synchronism check

Request a price and lead time

HighPROTEC MCA4 — protection of the point of connection of distributed generation to the MV grid. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8537 10 98 00
HS, 6 digits8537 10
CN (EU)8537 10 98
HTSUS (USA)8537 10 91 70
China customs tariff8537 10 90 90

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

Is the MCA4 certified to VDE-AR-N 4110?

Yes, TÜV Nord has certified the MCA4 as fully compliant with VDE-AR-N 4110. Type tests under IEC 60255-1:2009 were carried out at KEMA.

What CT secondary current is the MCA4 designed for?

The current inputs are designed for 1 A and 5 A CTs, and the relay has built-in test sockets.

Which facilities is the MCA4 suitable for besides wind and solar plants?

Biogas and cogeneration installations, industrial sites with their own generation, feeder and decoupling protection, and backup generator protection. The ABS and Lloyd’s Register marine approvals allow it to be installed on ships.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides