International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

ETOS power transformer automation and monitoring system

ETOS is a modular transformer control and monitoring system. In a single cabinet it combines the OLTC drive, an automatic voltage regulator, cooling control and sensor data acquisition.

Versions
ETOS IM (stand-alone cabinet), ETOS ED (with OLTC drive), ETOS TD (drive on OLTC head cover), ETOS MD-IV (for RMV-II)
Functions
OLTC drive, voltage regulation, cooling control, monitoring of the OLTC and the transformer
Sensors
connection of third-party sensors
Visualization
web HMI, MCONTROL 7″/10″ panels

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The system is available in several versions. ETOS IM is installed as a separate stand-alone cabinet, ETOS ED is combined with the OLTC drive, ETOS TD is mounted as a drive on the OLTC head cover, and ETOS MD-IV is intended for RMV-II. Besides voltage regulation and cooling control, the system monitors the OLTC and the transformer itself. Third-party sensors can be connected to it. Data is shown on a web HMI and on MCONTROL 7/10 inch panels.

Technical specifications

VersionsETOS IM (stand-alone cabinet), ETOS ED (with OLTC drive), ETOS TD (drive on OLTC head cover), ETOS MD-IV (for RMV-II)
FunctionsOLTC drive, voltage regulation, cooling control, monitoring of the OLTC and the transformer
Sensorsconnection of third-party sensors
Visualizationweb HMI, MCONTROL 7″/10″ panels

Request a price and lead time

ETOS power transformer automation and monitoring system. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)9032 89 00 00
HS, 6 digits9032 89
CN (EU)9032 89 00
HTSUS (USA)9032 89 60 85
China customs tariff9032 89 90 10

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

What functions does ETOS combine?

OLTC drive, automatic voltage regulation, cooling control and monitoring of the OLTC and the transformer.

What versions of the system are available?

ETOS IM in a stand-alone cabinet, ETOS ED with the OLTC drive, ETOS TD with a drive on the OLTC head cover, and ETOS MD-IV for RMV-II.

Can sensors from other manufacturers be connected?

Yes, the system accepts third-party sensors. Visualization is via the web HMI or MCONTROL 7/10 inch panels.