DI-2USB USB to RS-485 interface converter with galvanic separation
The DI-2USB links a PC or workstation by USB to devices with an RS-485 interface. It takes its power from the USB port. Input and output circuits are galvanically separated.
- Supply
- from USB port
- USB interface
- 1 x USB, type B
- RS-485 interface
- 1 x RS-485
- Baud rate
- 9.6…115.2 kbit/s
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
A PC or workstation with a USB port can reach a BMS network or Modbus RTU devices through the DI-2USB, with no change to the computer's hardware or software. Over the RS-485 interface, software can be used to parameterise MK800 and MK2430 alarm indicator and operator panels as well as Modbus RTU devices, and to evaluate BMS bus and Modbus RTU devices.
Galvanic separation of DC 3000 V between the input and output circuits protects the connected devices, and further internal measures guard against voltage spikes. The unit is powered from the USB port, so no extra supply is required. A USB cable and a driver CD are included. Insulation coordination follows IEC 60664-1, with a rated impulse voltage of 3 kV and pollution degree 3.
The RS-485 side runs at 9.6…115.2 kbit/s over a cable of up to 1200 m. Shielded J-Y(St)Y of at least 2 x 0.8, with the shield connected to PE at one end, is recommended. Integrated terminating resistors are selected by a jumper and are fitted at the factory. When connecting to a BMS bus, check the bus termination. The LEDs are ON (yellow), Rx Data (green) and Tx Data (red).
Terminals are screw-type for 0.5…2.5 mm² (AWG 22…12), and the computer end uses a USB type B plug. EMC follows EN 61000-6-2 and EN 61000-6-4. Climatic class to IEC 60721 is 3K5 in stationary use, 2K3 in transport and 1K4 in long-term storage. Operating temperature is -10…+55 °C.
Mounting is by 2 x M3 screws or on a DIN rail to IEC 60715, in any position, for continuous operation. Weight is up to 25 g.
Technical specifications
| Supply | from USB port |
|---|---|
| USB interface | 1 x USB, type B |
| RS-485 interface | 1 x RS-485 |
| Baud rate | 9.6…115.2 kbit/s |
| Cable length | ≤ 1200 m |
| Galvanic separation | DC 3000 V |
| Rated impulse voltage/pollution degree | 3 kV/3 |
| Conductor sizes | 0.5…2.5 mm² (AWG 22…12) |
| Operating temperature | -10…+55 °C |
| Weight | ≤ 25 g |
Part numbers
Show all part numbers (1)
B95012045
How it compares with similar models
| Parameter | DI-2USB USB to RS-485 interface converter with galvanic separation | DI-1DL RS-485 interface repeater for BMS bus and Modbus RTU | SMO482-12 BMS bus signal converter with 12 relay outputs | SMI473 signal converter, 12 digital inputs to BMS bus, RS-485 |
|---|---|---|---|---|
| Baud rate | 9.6…115.2 kbit/s | dynamic | 9.6 kbit/s | 9.6… 57.6 kbit/s |
| Operating temperature | -10…+55 °C | 0…+70 °C | -10…+55 °C | -10 … +55 °C |
| Weight | ≤ 25 g | approx. 90 g | 350 g | ≤ 320 g |
Request a price and lead time
DI-2USB USB to RS-485 interface converter with galvanic separation. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Does the DI-2USB need a separate power supply?
No, it is powered from the USB port. A USB cable and a driver CD are included.
What baud rate and cable length apply on the RS-485 side?
The baud rate is 9.6…115.2 kbit/s and the cable length is up to 1200 m. Terminating resistors are built in and selected by a jumper.
Which devices can be configured through it?
MK800 and MK2430 panels and Modbus RTU devices can be parameterised over RS-485. It also connects a PC to a BMS network.