LINETRAXX® CTUB103 AC/DC sensitive measuring current transformer, up to 25 A
The CTUB103 turns leakage and fault currents into a measurement signal and detects fault currents with a smooth DC component. Ranges are 5 A, 10 A and 25 A rms, accuracy ±2 %, supply DC 24 V.
- Rated voltage
- 800 V
- Supply voltage
- DC 24 V
- Measuring ranges
- 5 A rms, 10 A rms, 25 A rms
- Measurement accuracy
- ±2 %
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
A CTUB103 transformer pairs a CTBC… measuring core with a CTUB103 electronic module, and the two are combined to suit the application. The assembly converts system leakage and fault currents into a signal that can be evaluated, and it detects fault currents carrying a smooth DC component.
It can be fitted in DC, AC and 3(N)AC systems and in high-resistance grounded systems, where it monitors the star point. Evaluation is carried out by an NGRM… device to which the transformer is connected, for example the NGRM500 or NGRM700. Rated voltage is 800 V and the supply is DC 24 V.
Three cores are offered. The CTUB103-CTBC35 has a ø 35 mm opening and ranges of 5 A and 10 A; the CTUB103-CTBC60 (ø 60 mm) and CTUB103-CTBC120 (ø 120 mm) offer 5 A, 10 A and 25 A. A potentiometer sets the range, with scaling of 5 A/50 mA (100:1), 10 A/50 mA (200:1) and 25 A/50 mA (500:1). Measurement accuracy is ±2 %.
Rated continuous thermal current is 42 A, short-time thermal current 2.4 kA/1 s and dynamic current 6 kA/40 ms. Operating temperature is -25…55 °C. The cores weigh up to 310 g (CTBC35), 530 g (CTBC60) and 1460 g (CTBC120).
A multicolour LED reports operation, faults and status; green means normal operation and red flashing means a device error. The connection to the measuring core is monitored. The module slides onto the plug contacts of the core and can be exchanged without mechanically separating the primary conductors. On cores with an inner diameter of 120 mm or more, an offset calibration with button T is advised before first commissioning.
The version meets DIN EN 45545-2:2016 for railway vehicles, and the housing is rated UL94 V-0. Installation, connection and commissioning are for electrically skilled persons only.
Technical specifications
| Rated voltage | 800 V |
|---|---|
| Supply voltage | DC 24 V |
| Measuring ranges | 5 A rms, 10 A rms, 25 A rms |
| Measurement accuracy | ±2 % |
| Rated continuous thermal current | 42 A |
| Rated short-time thermal current | 2.4 kA/1 s |
| Rated dynamic current | 6 kA/40 ms |
| Operating temperature | -25…55 °C |
| Core opening | ø 35 mm, ø 60 mm, ø 120 mm |
| Weight CTBC35 | ≤ 310 g |
| Weight CTBC60 | ≤ 530 g |
| Weight CTBC120 | ≤ 1460 g |
Part numbers
Show all part numbers (11)
B78120030, B78120031, B78120032, B94053110, B94053111, B94053112, B98120003, B98120005, B98120007, B78120052, B91080112
How it compares with similar models
| Parameter | LINETRAXX® CTUB103 AC/DC sensitive measuring current transformer, up to 25 A | LINETRAXX® RCMB330 AC/DC sensitive residual current monitoring module, 10…500 mA, RS-485 | LINETRAXX® SmartDetect LCM410 Four-Channel Load Current Monitor, 6 mA…50 A | CTBC17 AC/DC sensitive measuring current transformers, 17 mm aperture |
|---|---|---|---|---|
| Rated voltage | 800 V | 800 V | — | 230/400 V (серія / series: 600 V) |
| Supply voltage | DC 24 V | DC 24 V (19.2…28.8 V) | DC 24 V | — |
| Operating temperature | -25…55 °C | — | -40…+85 °C | -35…+85 °C |
Request a price and lead time
LINETRAXX® CTUB103 AC/DC sensitive measuring current transformer, up to 25 A. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which measuring ranges does the CTUB103 offer?
5 A, 10 A and 25 A rms; the ø 35 mm version covers 5 A and 10 A.
What does the transformer connect to?
To an NGRM… device, for example the NGRM500 or NGRM700.
Is calibration needed?
On cores with an inner diameter of 120 mm or more, an offset calibration is advised before first commissioning.
Similar equipment from other manufacturers