International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

BESTCOMSPlus®, BESTdata, BEST61850™ — software for settings, event analysis and IEC 61850

A software suite for digital protection devices, excitation regulators and generator plant controllers. BESTCOMSPlus® configures and monitors devices, BESTdata analyzes recorded events, and BEST61850™ configures the IEC 61850 protocol. The programs are downloaded free of charge from the manufacturer's resource library.

BESTCOMSPlus
settings and monitoring of BE1-FLEX, BE1-700V, BE1-11, DECS-150/250/250E/250N/450, DGC-2020/2020ES/2020HD
Logic
graphical BESTlogic™Plus with offline simulation
Commissioning
real-time analysis and recording, step and frequency injection, phasor diagrams
BESTdata
COMTRADE record analysis, virtual channels, trajectories and vectors

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

BESTCOMSPlus® is the main settings and monitoring program for BE1-FLEX, BE1-700V, BE1-11, DECS-150, DECS-250, DECS-250E, DECS-250N, DECS-450, DGC-2020, DGC-2020ES and DGC-2020HD. This list includes the BE1-FLEX protection, automation and control system, the BE1-11 protection system and the BE1-700V voltage relay, the DECS digital excitation control systems, including DECS-250N with negative field forcing, and the DGC digital generator plant controllers. Digital devices have a huge number of configurable parameters. The program shows the device configuration clearly and helps manage the interaction of systems confidently during commissioning, operation and diagnostics. Settings are presented graphically and arranged in a menu tree.

The device logic is built in the BESTlogic™Plus graphical editor by dragging elements. This approach is simple to implement and reduces the likelihood of errors. Offline simulation and real-time display of logic states show how the device is configured and what it does at a specific moment. The scheme can be checked before going to site, and during operation it shows which logic elements have operated.

For measurements and commissioning the program has real-time data analysis and recording, step and frequency injection tools, control panels, phasor diagrams and extended measurement functions. They are used during commissioning, fault finding and compliance testing to NERC requirements. Step injection, for example, is used to check the response of the DECS exciter to a step change of the voltage setpoint.

BESTdata is designed for detailed analysis of previously recorded events, when basic amplitude measurements are not enough to find the root cause of a fault. Protection engineering services need it to analyze a fault after protection operation, when the sequence of events must be reconstructed. The program opens COMTRADE records, builds virtual channels, trajectories and vectors. BEST61850™ configures the IEC 61850 protocol, available as a BE1-FLEX option, and helps integrate devices of different manufacturers into the substation automation system.

All three programs are downloaded from the Resource Hub section of the manufacturer's website without paying a license fee. The devices they work with are designed and manufactured at plants in Highland, Illinois and Taylor, Texas, USA. The manufacturer also provides staff training at its base or at the customer's site, and technical support is available around the clock.

Technical specifications

BESTCOMSPlussettings and monitoring of BE1-FLEX, BE1-700V, BE1-11, DECS-150/250/250E/250N/450, DGC-2020/2020ES/2020HD
Logicgraphical BESTlogic™Plus with offline simulation
Commissioningreal-time analysis and recording, step and frequency injection, phasor diagrams
BESTdataCOMTRADE record analysis, virtual channels, trajectories and vectors
BEST61850IEC 61850 configuration for BE1-FLEX
Distributionfree download from the Resource Hub

Request a price and lead time

BESTCOMSPlus®, BESTdata, BEST61850™ — software for settings, event analysis and IEC 61850. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which devices does BESTCOMSPlus configure?

The program works with BE1-FLEX, BE1-700V and BE1-11, the DECS-150, DECS-250, DECS-250E, DECS-250N and DECS-450 exciters, and the DGC-2020, DGC-2020ES and DGC-2020HD controllers.

What is BEST61850 used for?

BEST61850™ configures the IEC 61850 protocol, which is available as a BE1-FLEX option. With it the device is integrated into the substation automation system together with equipment from other manufacturers.

What records does BESTdata analyze?

BESTdata opens event records in COMTRADE format and builds virtual channels, trajectories and vectors. The program is used to find the root causes of faults.

Similar equipment from other manufacturers