
7204/7220/9604/9620 Analogue Panel Meters for Insulation Monitoring Devices
Panel meters 7204/7220 (72 x 72 mm) and 9604/9620 (96 x 96 mm) indicate the value from the current output of an insulation monitoring device. Input is 0…400 µA or 0…20 mA; the S version withstands higher shock and vibration.
- Size
- 72 x 72 mm (7204/7220) or 96 x 96 mm (9604/9620)
- Input current
- 0…400 µA (7204/9604) / 0…20 mA (7220/9620)
- Accuracy class to DIN 43780
- 1.5
- Test voltage
- 3 kV
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The 7204/7220 and 9604/9620 analogue meters display measured values from the manufacturer's devices that have a matching current output. The typical use is a read-out of the insulation resistance from an ISOMETER®. The scale has a white background with black imprint, and the instruments use either a division scale or a scale with a segment display.
Models 7204 and 7220 measure 72 x 72 mm, models 9604 and 9620 measure 96 x 96 mm. The model sets the input current: 7204 and 9604 take 0…400 µA, 7220 and 9620 take 0…20 mA. When choosing a meter, the internal resistance of the insulation monitoring device has to be considered, and it must equal the scale centre point, for example 120 kΩ. In the type list, 0…400 µA is paired with IR470LY-4… and IRDH275/375 (72 x 72 mm) and with IR470LY2-6… (96 x 96 mm); 0…20 mA is paired with IRDH275B/375B/575.
The standard version has a polycarbonate enclosure that is self-extinguishing and non-melting (UL94V0). Several instruments can be mounted side by side without spacers. Connection is by hexagon head bolts with spring-loaded terminal bolts, and the terminals are protected against accidental contact.
The S version is built for harsh environmental conditions, for example on ships, and withstands increased shock and vibration. Test voltage is 3 kV, accuracy class to DIN 43780 is 1.5, normal position is vertical +5°, and the temperature range is -25…+40 °C. The enclosure is rated IP52 and the terminals IP00 (terminals with contact protection). The series is discontinued.
Technical specifications
| Size | 72 x 72 mm (7204/7220) or 96 x 96 mm (9604/9620) |
|---|---|
| Input current | 0…400 µA (7204/9604) / 0…20 mA (7220/9620) |
| Accuracy class to DIN 43780 | 1.5 |
| Test voltage | 3 kV |
| Normal position | vertical +5° |
| Temperature range | -25…+40 °C |
| Degree of protection | enclosure IP52, terminals IP00 (with contact protection) |
| Enclosure material | polycarbonate, UL94V0 |
| Scale | white background, black imprint |
| S version | increased shock and vibration resistance |
Part numbers
Show all part numbers (9)
7204-1421, 7204S-1421, 9604-1421, 9604S-1421, 9620-1421, 9620S-1421, 9604-1621, 7220-1421, 7220S-1421
Request a price and lead time
7204/7220/9604/9620 Analogue Panel Meters for Insulation Monitoring Devices. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which meter suits a 0…20 mA current output?
Models 7220 (72 x 72 mm) and 9620 (96 x 96 mm) take 0…20 mA; models 7204 and 9604 take 0…400 µA.
What mounting position and ambient range apply?
Normal position is vertical +5°, the temperature range is -25…+40 °C and the accuracy class to DIN 43780 is 1.5.
How does the S version differ from the standard one?
The S version has increased shock and vibration resistance and is built for harsh environmental conditions, for example on ships.
Similar equipment from other manufacturers






