SEL-487E — differential protection of power transformers

SEL-487E protects and monitors power transformers and autotransformers with up to seven terminals. The terminal detects turn-to-turn faults from 2% of the winding, with an operating time under 1.5 cycles.

Current inputs
up to 7 three-phase restraint groups, 18 inputs
Voltage inputs
0–300 V (ph-n)
Protocols
IEC 61850 Ed.2.1, DNP3, PRP, PTPv2, IEEE C37.118 synchrophasors
Digital substation
optional TiDL or Sampled Values IEC 61850-9-2 / IEC 61869-9

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The terminal performs thermal monitoring and accounts for through-fault currents. Up to 7 three-phase restraint groups are connected, 18 current inputs in total, plus 0–300 V (ph-n) voltage inputs. Three independent REF elements are provided. Protocols are IEC 61850 Ed.2.1, DNP3, PRP, PTPv2 and IEEE C37.118 synchrophasors. Digital substations are supported via TiDL or Sampled Values per IEC 61850-9-2 / IEC 61869-9.

Technical specifications

Current inputsup to 7 three-phase restraint groups, 18 inputs
Voltage inputs0–300 V (ph-n)
ProtocolsIEC 61850 Ed.2.1, DNP3, PRP, PTPv2, IEEE C37.118 synchrophasors
Digital substationoptional TiDL or Sampled Values IEC 61850-9-2 / IEC 61869-9
REF3 independent elements
Operating timeunder 1.5 cycles
Turn-to-turn faultsfrom 2% of the winding

Request a price and lead time

SEL-487E — differential protection of power transformers. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8536 49 00 90
HS, 6 digits8536 49
CN (EU)8536 49 00
HTSUS (USA)8536 49 00 80
China customs tariff8536 49 00 90

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

How many terminals does the SEL-487E cover?

Up to 7 three-phase restraint current groups, 18 current inputs in total.

Which turn-to-turn faults does the terminal detect?

Turn-to-turn faults from 2% of the winding, with an operating time under 1.5 cycles.

Does the SEL-487E support a digital substation?

Optionally, through TiDL or Sampled Values per IEC 61850-9-2 / IEC 61869-9.