SEL-487B — busbar differential protection and breaker failure protection

SEL-487B provides low-impedance busbar differential protection with a breaker failure protection function for high-voltage substations. The terminal accepts up to 21 current inputs of 1 A / 5 A, with an operating time under one cycle.

Current inputs
up to 21 (1 A / 5 A)
Voltage inputs
0–300 V (ph-n)
Protocols
IEC 61850 Ed.2.1, DNP3, PRP, PTPv2, IEEE C37.118 synchrophasors
Digital substation
optional TiDL or Sampled Values IEC 61850-9-2 / IEC 61869-9

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Zones are configured dynamically, with a check zone, backup overcurrent protection and 0–300 V (ph-n) voltage inputs for tripping verification. Digital substations are supported via TiDL or Sampled Values per IEC 61850-9-2 / IEC 61869-9. Communication: IEC 61850 Ed.2.1, DNP3, PRP, PTPv2 and IEEE C37.118 synchrophasors.

Technical specifications

Current inputsup to 21 (1 A / 5 A)
Voltage inputs0–300 V (ph-n)
ProtocolsIEC 61850 Ed.2.1, DNP3, PRP, PTPv2, IEEE C37.118 synchrophasors
Digital substationoptional TiDL or Sampled Values IEC 61850-9-2 / IEC 61869-9
Principlelow-impedance busbar differential protection, operating time under one cycle

Request a price and lead time

SEL-487B — busbar differential protection and breaker failure protection. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8536 49 00 90
HS, 6 digits8536 49
CN (EU)8536 49 00
HTSUS (USA)8536 49 00 80
China customs tariff8536 49 00 90

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

How many feeders can be connected to the SEL-487B?

The terminal accepts up to 21 current inputs of 1 A / 5 A.

How fast is the busbar protection?

Low-impedance busbar differential protection operates in less than one cycle.

Does the terminal include breaker failure protection?

Yes, it is built in together with backup overcurrent protection and the check zone.