SEL-451 combines substation bay control with high-speed circuit breaker protection and breaker switching-life monitoring. The SEL-352 performs the specialised functions of a breaker failure protection device.

Current inputs
1 A / 5 A
Voltage inputs
0–300 V (phase-to-neutral)
Protocols
IEC 61850 Ed.2.1, DNP3, PRP, PTPv2, synchrophasors IEEE C37.118
Digital substation
optionally TiDL or Sampled Values per IEC 61850-9-2 / IEC 61869-9

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The SEL-451 controls bay breakers and disconnectors and performs IEEE C37.118 synchrophasor measurements. The SEL-352 breaker failure function is single-pole or three-pole, with incomplete-phase and open-contact flashover monitoring.

Current inputs 1 A / 5 A, voltage inputs 0–300 V. Communication over IEC 61850 Ed.2.1 and DNP3, PRP redundancy, PTPv2 synchronisation, optionally TiDL or Sampled Values per IEC 61850-9-2 / IEC 61869-9.

Technical specifications

Current inputs1 A / 5 A
Voltage inputs0–300 V (phase-to-neutral)
ProtocolsIEC 61850 Ed.2.1, DNP3, PRP, PTPv2, synchrophasors IEEE C37.118
Digital substationoptionally TiDL or Sampled Values per IEC 61850-9-2 / IEC 61869-9
Functionsbay control, breaker failure protection, breaker switching-life monitoring
SEL-352single-pole and three-pole breaker failure, incomplete-phase operation, flashover across open contacts

Request a price and lead time

SEL-451 / SEL-352 — circuit breaker protection and bay control. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8536 49 00 90
HS, 6 digits8536 49
CN (EU)8536 49 00
HTSUS (USA)8536 49 00 80
China customs tariff8536 49 00 90

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

What functions does the SEL-451 perform?

Bay control, breaker failure protection and breaker switching-life monitoring, plus synchrophasor measurements per IEEE C37.118.

How does the SEL-352 differ from the SEL-451?

The SEL-352 is a dedicated breaker failure device, single-pole or three-pole, with detection of incomplete-phase operation and flashover across open contacts.

What current and voltage inputs does the SEL-451 have?

Current inputs are 1 A / 5 A and voltage inputs are 0–300 V (phase-to-neutral).