Distance and directional protection, automation and control terminals for power lines SEL-421, SEL-311C and SEL-9L, with up to 5 distance protection zones using mho and quadrilateral characteristics. Current inputs are 1 A / 5 A, voltage inputs 0–300 V phase-to-neutral, with single and three-pole tripping.
- Current inputs
- 1 A / 5 A
- Voltage inputs
- 0–300 V (ph-n)
- Protocols
- IEC 61850 Ed.2.1, DNP3, PRP, PTPv2, IEEE C37.118 synchrophasors
- Digital substation
- optional TiDL or Sampled Values per IEC 61850-9-2 / IEC 61869-9
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The SEL-421 has five zones and controls a two-breaker bay, the SEL-311C has four zones and four-shot autoreclosing, and the new SEL-9L is built on the 9 Series platform and powered from 48–250 V. Logic prevents zone overreach caused by capacitive VTs and covers lines with series compensation. Protocols are IEC 61850 Ed.2.1, DNP3, PRP, PTPv2 and IEEE C37.118 synchrophasors. TiDL or Sampled Values per IEC 61850-9-2 / IEC 61869-9 are optional.
Technical specifications
| Current inputs | 1 A / 5 A |
|---|---|
| Voltage inputs | 0–300 V (ph-n) |
| Protocols | IEC 61850 Ed.2.1, DNP3, PRP, PTPv2, IEEE C37.118 synchrophasors |
| Digital substation | optional TiDL or Sampled Values per IEC 61850-9-2 / IEC 61869-9 |
| Zones | up to 5 distance protection zones (mho, quadrilateral) |
| Tripping | single- and three-pole |
| Control | two-breaker bay |
| SEL-9L power supply | 48–250 V |
Request a price and lead time
SEL-421 / SEL-311C / SEL-9L — distance protection for power lines. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Customs codes
| UKTZED (Ukraine) | 8536 49 00 90 |
|---|---|
| HS, 6 digits | 8536 49 |
| CN (EU) | 8536 49 00 |
| HTSUS (USA) | 8536 49 00 80 |
| China customs tariff | 8536 49 00 90 |
Codes are for reference: the final code is determined at declaration for the specific model.
Questions and answers
How many distance protection zones do the terminals have?
Up to 5 zones with mho and quadrilateral characteristics. The SEL-421 has five zones and the SEL-311C has four.
Do the terminals support a digital substation?
Yes, TiDL or Sampled Values per IEC 61850-9-2 / IEC 61869-9 are available as options. Communication runs over IEC 61850 Ed.2.1, DNP3, PRP and PTPv2.
What are the analog inputs and the power supply?
Current inputs 1 A / 5 A, voltage inputs 0–300 V phase-to-neutral. The SEL-9L is powered from 48–250 V.