SEL-400G — comprehensive protection of generator and generator-transformer unit

SEL-400G provides primary and backup protection of a generator together with busbars and the unit transformer in one device. The terminal has 18 current inputs and 6 voltage inputs of 0–300 V, with a frequency range of 5–120 Hz.

Current inputs
18 (5 A / 1 A / 0.2 A)
Voltage inputs
6, 0–300 V
Frequency range
5–120 Hz
Functions
generator, busbar and unit transformer protection, transverse differential protection, auto-synchronizing

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

It suits all generator types: hydro, pumped-storage, steam and gas turbine. Current inputs accept 5 A, 1 A or 0.2 A, and the CTs of the generator, busbars and unit transformer connect to one device. Transverse differential protection detects turn-to-turn faults, and auto-synchronizing is built in. SCADA communication runs over IEC 61850 Ed.2.1, Modbus TCP and DNP3, with PRP redundancy and PTPv2 time sync.

Technical specifications

Current inputs18 (5 A / 1 A / 0.2 A)
Voltage inputs6, 0–300 V
Frequency range5–120 Hz
Functionsgenerator, busbar and unit transformer protection, transverse differential protection, auto-synchronizing
ProtocolsIEC 61850 Ed.2.1, Modbus TCP, DNP3, PRP, PTPv2

Request a price and lead time

SEL-400G — comprehensive protection of generator and generator-transformer unit. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8536 49 00 90
HS, 6 digits8536 49
CN (EU)8536 49 00
HTSUS (USA)8536 49 00 80
China customs tariff8536 49 00 90

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

Which generators is the SEL-400G suitable for?

Generators of any type at hydro, pumped-storage, steam and gas turbine plants. The terminal also protects busbars and the unit transformer.

How many analog inputs does the terminal have?

18 current inputs at 5 A, 1 A or 0.2 A, and 6 voltage inputs of 0–300 V.

Which communication protocols does the SEL-400G support?

IEC 61850 Ed.2.1, Modbus TCP, DNP3, PRP redundancy and PTPv2 time synchronization.