International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

TOSMAP-DS/LX: D-AVR and D-EHC digital generator excitation and steam turbine control systems

D-AVR and D-EHC are digital turbine-generator control systems on the TOSMAP-DS/LX platform. D-AVR automatically regulates generator excitation, D-EHC controls and protects the steam turbine. The systems are installed on new steam turbine and combined-cycle units and in upgrades of thermal and nuclear plants.

Platform
TOSMAP-DS/LX (microprocessor controller for turbine and generator)
D-AVR
digital automatic excitation regulator, voltage and reactive power control
D-EHC
digital electro-hydraulic control and protection system for the steam turbine
Redundancy
triple (controllers and I/O network)

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The TOSMAP-DS/LX platform (Microprocessor Aided Power system control, Dynastream) consists of microprocessor controllers developed specifically for steam turbine and generator control. The hardware platform is common to both systems, so the excitation regulator and the turbine controller work in one control network. The controllers have triple redundancy and the control network is redundant too, so the failure of one channel does not stop the unit. Above them runs an information network with operator stations, and on request remote monitoring over the internet in 24/7 mode is added, so specialists see the system status without travelling to the station.

D-AVR regulates the generator voltage and reactive power and thus improves power system stability. The manufacturer has over 100 years of experience in designing and building control systems for synchronous generators, and this experience is built into the latest generation of excitation systems. The regulator is supplied both for the manufacturer's own turbogenerators and for machines of other makers, for example when upgrading the excitation systems of operating stations. In an upgrade the old analog regulator is replaced without replacing the generator itself. Over 500 D-AVR systems are installed worldwide.

D-EHC controls the steam turbine from start-up to shutdown and protects it over the whole operating range, so unit availability and safety depend on it. Turbine start-up is fully automatic. The optimized start-up function relies on a predictive model of rotor thermal stress. The speed of run-up and load pickup is modulated so as to keep the rotor surface temperature within the required limits and shorten the start-up time. This reduces fatigue loading of the rotor and preserves its life under frequent starts. The controllers have extended monitoring and a convenient operator interface. Over 350 D-EHC systems are installed.

The systems are used on new steam turbine and combined-cycle units and for upgrading excitation and turbine control at operating thermal and nuclear plants. They are supplied as a set with TX series steam turbines and the manufacturer's turbogenerators, while for generators of other makers D-AVR is installed separately. The long experience in designing and building control systems for steam turbines, which the company has produced since 1927, is built into the latest generation of D-EHC.

Technical specifications

PlatformTOSMAP-DS/LX (microprocessor controller for turbine and generator)
D-AVRdigital automatic excitation regulator, voltage and reactive power control
D-EHCdigital electro-hydraulic control and protection system for the steam turbine
Redundancytriple (controllers and I/O network)
Installedover 500 D-AVR and over 350 D-EHC
CompatibilityD-AVR - also for generators of other makers

Request a price and lead time

TOSMAP-DS/LX: D-AVR and D-EHC digital generator excitation and steam turbine control systems. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8504 40 88 00
9032 89 00 00
HS, 6 digits9032 89
8504 40
CN (EU)8504 40 88
9032 89 00
HTSUS (USA)8504 40 95 80
9032 89 60 90
China customs tariff8504 40 99 99
9032 89 90 90

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

Is D-AVR suitable for generators of other makers?

Yes, D-AVR is supplied both for the manufacturer's own turbogenerators and for machines of other makers, including excitation upgrades. Over 500 such systems are installed worldwide.

Which functions does D-EHC perform?

The system controls the steam turbine from start-up to shutdown, protects it over the whole operating range and performs automatic start-up based on a predictive model of rotor thermal stress. Over 350 systems are installed.

How are the TOSMAP-DS/LX controllers made redundant?

The controllers have triple redundancy and the control network is redundant too. Remote 24/7 monitoring is added on request.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides