Power Unit — MV station for solar plants and energy storage (PCS + transformer 6.6–36 kV), up to 10 MVA

Power Unit is a compact low-noise medium-voltage station in a plug and play format for solar power plants and energy storage systems. It combines one or two water-cooled PCS converters, a transformer and protective equipment, and delivers up to 10 MVA in a 30-foot format enclosure.

Rating
Single PCS up to 5057 kVA; Dual PCS up to 10 115 kVA (at 1500 V DC, 40 °C)
DC voltage
up to 1500 V (2000 V ready); min. 463/981/1037 V
DC current
Single 2 × 2450 A or 4900 A; Dual 4 × 2450 A or 2 × 4900 A
AC voltage (MV)
6.6–36 kV ±10 %, 50/60 Hz ±6 %

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Power Unit comprises a medium-voltage switchgear, a power transformer and PCS converters on a common skid. The Single PCS version delivers up to 5057 kVA (at 1500 V DC and 40 °C), and the Dual PCS version up to 10 115 kVA. The PCS units are water-cooled. The station is designed for networks with a growing share of non-dispatchable generation.

The maximum DC voltage is 1500 V with readiness for the 2000 V standard, and the minimum is 463, 981 or 1037 V depending on the version. The DC current is 2 × 2450 A or 4900 A in the Single version and 4 × 2450 A or 2 × 4900 A in the Dual version, with up to 30 and up to 60 DC inputs respectively. The rated AC voltage is from 6.6 to 36 kV ±10 %, the frequency is 50/60 Hz ±6 %, and THDi is below 1 % at rated power. The maximum PCS efficiency is 98.7 %, and standby consumption is below 250 W. Grid forming and black start are supported. The power factor range at the source is given as from 0 (underexcited) to 0 (overexcited), which looks like an error, so confirm the value. Communication is via Modbus TCP/IP, optionally Profinet, and preparation for remote monitoring is provided.

The transformer has ONAN/KNAN cooling, with a choice of standard losses or Ecodesign 2 requirements, and Type C connectors. Protection comprises DC disconnectors and surge arresters, a medium-voltage circuit breaker, and surge arresters on the AC side and in the auxiliary circuits.

The dimensions of the Single version are 6058 × 2438 × 2896 mm with a weight of 20 t, and of the Dual version 9125 × 2438 × 2896 mm with 30 t. According to the datasheet notes, dimensions and weight depend on the configuration. The temperature range is -20…+40 °C, optionally -40 °C, and the notes state a 10 % power derating at 50 °C. The altitude is up to 1000 m without derating, and up to 4000 m with current and voltage derating. Corrosion protection is C4H, optionally C5H.

The station meets the requirements of CE, UKCA and UL and the standards EN IEC 60076, 62271-1/-100/-102/-200/-213, 62920, 62477-1 and 62443. The manufacturer's quality system is certified to ISO 9001:2015. Applications are grid energy storage, utility-scale solar plants, hybrid power plants and connection to 6.6–36 kV networks.

Technical specifications

RatingSingle PCS up to 5057 kVA; Dual PCS up to 10 115 kVA (at 1500 V DC, 40 °C)
DC voltageup to 1500 V (2000 V ready); min. 463/981/1037 V
DC currentSingle 2 × 2450 A or 4900 A; Dual 4 × 2450 A or 2 × 4900 A
AC voltage (MV)6.6–36 kV ±10 %, 50/60 Hz ±6 %
TransformerONAN/KNAN; standard losses or Ecodesign 2
MV protectionmedium-voltage circuit breaker
THDi< 1 %
PCS efficiencyup to 98.7 %
Dimensions / weight6058 × 2438 × 2896 mm, 20 t (Single); 9125 × 2438 × 2896 mm, 30 t (Dual)
Functionsgrid forming, black start
StandardsCE, UKCA, UL; EN IEC 60076, 62271, 62920, 62477-1, 62443

Request a price and lead time

Power Unit — MV station for solar plants and energy storage (PCS + transformer 6.6–36 kV), up to 10 MVA. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What power does Power Unit deliver in the Single and Dual versions?

Single PCS up to 5057 kVA, Dual PCS up to 10 115 kVA at 1500 V DC and 40 °C. The station fits in a 30-foot format enclosure.

What networks can the station be connected to?

The rated AC voltage is from 6.6 to 36 kV ±10 %, and the frequency is 50/60 Hz ±6 %. THDi is below 1 % at rated power.

What are the dimensions and weight of the Single and Dual versions?

Single 6058 × 2438 × 2896 mm, weight 20 t. Dual 9125 × 2438 × 2896 mm, weight 30 t. Dimensions and weight depend on the final configuration.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides