Under-oil surge arresters for distribution transformers, MCOV 2.55 to 22 kV

Under-oil arresters are immersed in insulating oil inside distribution transformers and other oil-filled equipment, classed as IEEE Heavy Duty and IEC Distribution High. They meet IEEE C62.11 and IEC 60099-4, cover systems from 2.5 to 36 kV and undergo 100% acceptance testing.

Type
under-oil surge arrester
Class
IEEE Heavy Duty / IEC Distribution High
System voltage
2.5 to 36 kV
MCOV
2.55; 5.1; 7.65; 8.4; 10.2; 12.7; 15.3; 17; 22 kV

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Under-oil arresters are installed inside the tank of distribution transformers and other oil-filled equipment. Placing the arrester in oil shortens the connection to the winding, protects it from contamination and vandalism, and keeps the dielectric strength of the oil, which prevents insulation breakdown. They are used at substations and in distribution networks with voltages from 2.5 to 36 kV.

The active part uses MOV varistor discs. The arrester belongs to the IEEE Heavy Duty and IEC Distribution High classes and follows the current editions of IEEE C62.11 and IEC 60099-4. Each arrester passes 100% acceptance testing, and the network frequency is 48-62 Hz.

The available MCOV values are 2.55, 5.1, 7.65, 8.4, 10.2, 12.7, 15.3, 17 and 22 kV. The duty cycle voltages are 3, 6, 9, 12, 15, 18 and 21 kV respectively for models up to 17 kV. The BIL is 75 kV for 2.55 and 5.1 kV, 95 kV for 7.65 and 10.2 kV, and 125 kV for 12.7 to 17 kV. The active part length increases from 3.71 in at 2.55 kV to 5.73, 6.77, 7.67, 8.76 and 9.45 in.

Each MCOV is supplied in two mounting versions: 3001 with a bracket and 3002 without a bracket. The current rating is 2000 A for 5.1 kV, 1000 A for 7.65 kV and 500 A for models from 10.2 kV. For model 2211053001 (5.1 kV) the residual voltage is 16.83 kV at 1.5 kA, 18.54 kV at 5 kA and 22.02 kV at 20 kA, and the maximum switching surge is 15.69 kV. For 2211033002 (2.55 kV) it is 8.43 kV at 1.5 kA and 11.04 kV at 20 kA. The 8.4 kV versions weigh 2 lb and the 22 kV versions weigh 4.4 lb.

Technical specifications

Typeunder-oil surge arrester
ClassIEEE Heavy Duty / IEC Distribution High
System voltage2.5 to 36 kV
MCOV2.55; 5.1; 7.65; 8.4; 10.2; 12.7; 15.3; 17; 22 kV
Duty cycle voltage3 to 21 kV
BIL75; 95; 125 kV
Rated current2000 A (5.1 kV), 1000 A (7.65 kV), 500 A (from 10.2 kV)
Residual voltage 221105300116.83 kV at 1.5 kA; 22.02 kV at 20 kA
Length3.71 to 9.45 in
Mounting3001 with bracket, 3002 without bracket
Frequency48-62 Hz
Weight2 lb (8.4 kV), 4.4 lb (22 kV)
StandardsIEEE C62.11, IEC 60099-4

Part numbers

Show all part numbers (16)

2211033001, 2211033002, 2211053001, 2211053002, 2211083001, 2211093001, 2211093002, 2211103001, 2211103002, 2211133001, 2211133002, 2211153001, 2211173001, 2211173002, 2211223001, 2211223002

Request a price and lead time

Under-oil surge arresters for distribution transformers, MCOV 2.55 to 22 kV. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How do the 3001 and 3002 versions differ?

The 3001 version comes with a bracket for mounting inside the tank, while the 3002 has no bracket. Electrical parameters are the same for the same MCOV.

Which MCOV should be chosen for a transformer network?

MCOV is chosen by the highest continuous phase-to-earth voltage, and the series runs from 2.55 to 22 kV. For example, 2211103001 has an MCOV of 10.2 kV and a BIL of 95 kV.

Which standards does the arrester meet?

IEEE C62.11 for the Heavy Duty class and IEC 60099-4 for the Distribution High class.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides