International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

SBKT polymer tube-housed surge arrester up to 800 kV

SBKT surge arrester in a composite tube housing for high and extra-high voltage substations with Um up to 550 kV, with some versions up to 800 kV. It is designed for high mechanical and seismic requirements and can double as a post insulator.

Highest system voltage Um
up to 550 kV (versions up to 800 kV)
Housing
fibreglass tube with silicone sheds (LSR)
Mechanical load SSL
up to 23 kN·m
Versions
BF-I, BF-II, including for pressure relief current of 80 kA

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Fibreglass tube housing with LSR silicone sheds. The mechanical load SSL is up to 23 kN·m, and after a short circuit it retains 75 % of its mechanical strength. The series is available in BF-I and BF-II versions, including for a pressure relief current of 80 kA. Design and testing to IEC 60099-4.

Technical specifications

Highest system voltage Umup to 550 kV (versions up to 800 kV)
Housingfibreglass tube with silicone sheds (LSR)
Mechanical load SSLup to 23 kN·m
VersionsBF-I, BF-II, including for pressure relief current of 80 kA
Featuresretains 75 % of mechanical strength after a short circuit; can serve as a post insulator
StandardIEC 60099-4

Request a price and lead time

SBKT polymer tube-housed surge arrester up to 800 kV. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8535 40 00 00
HS, 6 digits8535 40
CN (EU)8535 40 00
HTSUS (USA)8535 40 00 00
China customs tariff8535 40 00 00

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

What network voltage is the SBKT available for?

Basically for Um up to 550 kV, some versions up to 800 kV.

Can the SBKT be used as a post insulator?

Yes, with a mechanical load SSL of up to 23 kN·m the arrester can serve as a post insulator.

What happens to the housing after a short circuit?

After a short circuit the device retains 75 % of its mechanical strength, and a version for a pressure relief current of 80 kA is available.