SBKC polymer-housed surge arrester (cage design) up to 420 kV

SBKC metal-oxide surge arrester in a silicone housing of cage design for substations and overhead lines with Um up to 420 kV. It can be installed upright or suspended and does not fail explosively on overload.

Highest system voltage Um
up to 420 kV
Housing
LSR silicone, direct moulding over a cage of glass-epoxy rods
Gas volume
none, no pressure relief device
Mechanical load SSL
up to 4 kN·m

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The cage of glass-epoxy rods is moulded directly in LSR silicone, so there is no gas volume in the device and no pressure relief device is needed. The permissible mechanical load SSL is up to 4 kN·m. The series is available in Station Low, Medium and High versions (SL, SM, SH) to IEC 60099-4. In terms of price-to-performance ratio, SBKC compares favourably among substation surge arresters.

Technical specifications

Highest system voltage Umup to 420 kV
HousingLSR silicone, direct moulding over a cage of glass-epoxy rods
Gas volumenone, no pressure relief device
Mechanical load SSLup to 4 kN·m
VersionsStation Low / Medium / High (SL, SM, SH)
StandardIEC 60099-4

Request a price and lead time

SBKC polymer-housed surge arrester (cage design) up to 420 kV. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8535 40 00 00
HS, 6 digits8535 40
CN (EU)8535 40 00
HTSUS (USA)8535 40 00 00
China customs tariff8535 40 00 00

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

What network voltage is the SBKC rated for?

The arrester is used in networks with a highest voltage Um of up to 420 kV, at substations and on overhead lines.

Does the arrester have a pressure relief device?

No, the cage is moulded in LSR silicone with no gas volume, so a pressure relief device is not needed.

What mechanical load can the SBKC withstand?

The permissible mechanical load SSL is up to 4 kN·m, for upright or suspended mounting.