International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

SB-B / SBKW DC surge arresters for DC traction networks 1–4.5 kV

SB-B / SBKW DC surge arresters with continuous operating voltage Uc 1–4.5 kV. They protect DC overhead contact lines, traction substations, electric rolling stock and trolleybuses from lightning and switching overvoltages.

Continuous operating voltage Uc (DC)
1–4.5 kV
Classes
DC-B (SB-B porcelain, SBKW DC-B), DC-C (SBKW DC-C)
Nominal discharge current
10 kA (DC-B) / 20 kA (DC-C)
High-current 4/10 impulse
100 / 200 kA

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Made in porcelain and silicone housings. Class DC-B is represented by the porcelain SB-B and the silicone SBKW DC-B, class DC-C by the silicone SBKW DC-C. The nominal discharge current is 10 kA for DC-B and 20 kA for DC-C, the specific energy capability 12 / 28 kJ/kV Ur. Complies with IEC 62848-1, IEC 61373 and EN 45545-2.

Technical specifications

Continuous operating voltage Uc (DC)1–4.5 kV
ClassesDC-B (SB-B porcelain, SBKW DC-B), DC-C (SBKW DC-C)
Nominal discharge current10 kA (DC-B) / 20 kA (DC-C)
High-current 4/10 impulse100 / 200 kA
Specific energy capability12 / 28 kJ/kV Ur
StandardsIEC 62848-1, IEC 61373, EN 45545-2

Request a price and lead time

SB-B / SBKW DC surge arresters for DC traction networks 1–4.5 kV. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8535 40 00 00
HS, 6 digits8535 40
CN (EU)8535 40 00
HTSUS (USA)8535 40 00 00
China customs tariff8535 40 00 00

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

What operating voltage are the arresters rated for?

Continuous DC operating voltage Uc from 1 to 4.5 kV.

How do classes DC-B and DC-C differ?

DC-B has a nominal discharge current of 10 kA and an energy capability of 12 kJ/kV Ur, DC-C 20 kA and 28 kJ/kV Ur respectively.

Can the arresters be installed on rolling stock?

Yes, the series is used on electric rolling stock and trolleybuses and complies with IEC 61373 and EN 45545-2.