PDV-65 Optima normal-duty distribution arrester, IEC 60099-4 Ed. 3.0 class DM, 2.5–36 kV

A polymer-housed metal-oxide arrester for medium-voltage distribution networks between 2.5 and 36 kV. It is tested to IEC 60099-4 Edition 3.0 as a Distribution Medium arrester and sits in the IEEE normal-duty class.

Class
IEC Distribution Medium / IEEE normal duty
Standard
IEC 60099-4 Edition 3.0
System voltage
2.5–36 kV
Uc / MCOV (part 294003C4CC)
2.55 kV

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

For general overhead distribution, where surge energy is moderate and units go up in large numbers, the Distribution Medium class of IEC 60099-4 Edition 3.0 is usually enough. PDV-65 Optima fills that slot on 2.5–36 kV networks, guarding pole-mounted transformers, cable risers and line equipment against lightning and switching overvoltages.

The reference part, 294003C4CC, has Uc 2.55 kV and Ur 3 kV and comes on an insulating bracket with disconnector. Residual voltage reads 8.1 kV at 1.5 kA, 10.4 kV at 10 kA and 15 kV at 40 kA; the 0.5 µs front-of-wave figure at classifying current is 10.5 kV, and the switching surge level is 7.3 kV. Pressure relief is 16 kA symmetrical rms, and the long-duration test is 75 A for 2000 µs.

Metal-oxide discs are moulded into a grey ESP™ polymer housing with a triple dynamic seal against moisture. The capacitive disconnector operates from 1 A of fault current, and each unit is routine tested. Creepage distance on the reference part is 338 mm (13.3 in).

Part numbers differ by Uc rating and hardware, with versions with and without the insulating bracket. Mounting is upright, frequency 48–62 Hz, and the stated maximum altitude is 12000 ft. Overall size of the reference part is 10.137 × 6.82 × 3.63 in. Tell us the network voltage, earthing and pole hardware, and we will propose the matching part.

Technical specifications

ClassIEC Distribution Medium / IEEE normal duty
StandardIEC 60099-4 Edition 3.0
System voltage2.5–36 kV
Uc / MCOV (part 294003C4CC)2.55 kV
Ur (duty cycle)3 kV
Residual voltage8.1 kV @ 1.5 kA; 10.4 kV @ 10 kA; 15 kV @ 40 kA
Switching surge, max.7.3 kV
0.5 µs discharge voltage10.5 kV
Pressure relief16 kA sym. rms
LCLD test75 A, 2000 µs
Creepage distance338 mm (13.3 in)
Frequency48–62 Hz
Maximum altitude12000 ft
HousingESP™ polymer, grey
Mountinginsulating bracket with disconnector

How it compares with similar models

ParameterPDV-65 Optima normal-duty distribution arrester, IEC 60099-4 Ed. 3.0 class DM, 2.5–36 kVPDV-100 Optima IEC Distribution High arrester, M12 stud, for 2.5–36 kV networksPDV-100 Optima heavy-duty polymer surge arrester to IEEE C62.11, 2.5–36 kV networksPDV-65 Optima Normal Duty Distribution Arresters for 2.5–36 kV Networks
ClassIEC Distribution Medium / IEEE normal dutyIEC Distribution High / IEEE heavy dutyIEEE heavy duty, distributionNormal Duty (IEEE); Distribution Medium (IEC)
StandardIEC 60099-4 Edition 3.0IEC 60099-4 Edition 3.0IEEE C62.11IEEE C62.11
Residual voltage8.1 kV @ 1.5 kA; 10.4 kV @ 10 kA; 15 kV @ 40 kA8 kV @ 1.5 kA; 9.9 kV @ 10 kA; 13.3 kV @ 40 kA8 kV @ 1.5 kA; 9.9 kV @ 10 kA; 13.3 kV @ 40 kA—
Pressure relief16 kA sym. rms20 kA sym. rms20 kA sym. rms15 kA
LCLD test75 A, 2000 µs250 A, 2000 µs250 A, 2000 µs—
Creepage distance338 mm (13.3 in)215 mm (8.5 in)215 mm (8.5 in)—

Request a price and lead time

PDV-65 Optima normal-duty distribution arrester, IEC 60099-4 Ed. 3.0 class DM, 2.5–36 kV. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How does PDV-65 Optima compare with PDV-100 Optima?

PDV-65 Optima is the normal-duty, Distribution Medium range; PDV-100 Optima belongs to the higher-energy class. Part 294003C4CC runs its long-duration test at 75 A.

Is a disconnector included?

Part 294003C4CC is supplied on an insulating bracket with a capacitive disconnector that operates from 1 A of fault current.

Is there an altitude limit?

The reference part is rated for installation up to 12000 ft.

Similar equipment from other manufacturers