International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

IEC 60099-4 distribution surge arresters for 2.5–36 kV networks

Surge arresters for medium-voltage distribution networks from 2.5 kV to 36 kV, built to IEC 60099-4 in the Distribution Medium and Distribution High classes. They keep lightning and switching overvoltages away from transformer and switchgear insulation.

Purpose
protection against lightning and switching overvoltages
Standard
IEC 60099-4
System voltage
2.5–36 kV
Classes
Distribution Medium, Distribution High

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

System voltages from 2.5 kV up to 36 kV are covered, the usual span of medium-voltage grids designed to IEC practice. The governing standard is IEC 60099-4, with Distribution Medium and Distribution High as the main classes, and every unit is routine tested at the works, so 100% of output is checked.

The range is split into four groups. Distribution Medium and Distribution High serve overhead feeders and distribution points; Station Low suits smaller substations; Under Oil arresters are fitted inside oil-filled apparatus such as transformers.

In operation the arrester waits between phase and earth, passing only a negligible current. A lightning strike or a switching event raises the voltage, the arrester diverts the surge current to earth and holds the stress on nearby insulation within safe limits.

Fit it as close as practical to the apparatus being protected and keep the earth lead short and straight. For an enquiry, tell us the system voltage, the neutral earthing arrangement, the mounting position and the IEC 60099-4 group required, and we will propose a version and send the documentation.

Technical specifications

Purposeprotection against lightning and switching overvoltages
StandardIEC 60099-4
System voltage2.5–36 kV
ClassesDistribution Medium, Distribution High
GroupsDistribution Medium, Distribution High, Station Low, Under Oil
Testingroutine tests on 100% of units

How it compares with similar models

ParameterIEC 60099-4 distribution surge arresters for 2.5–36 kV networksPolymer-housed distribution surge arresters to IEEE C62.11, normal and heavy dutyStation and intermediate class surge arresters to IEEE C62.11, polymer or porcelain housedMH4 and PH4 Station High Surge Arresters to IEC 60099-4, 36–420 kV Systems
Purposeprotection against lightning and switching overvoltagesprotection of distribution networks against lightning and switching overvoltagesprotection against lightning and switching overvoltages—
StandardIEC 60099-4IEEE C62.11IEEE C62.11—
ClassesDistribution Medium, Distribution HighNormal Duty, Heavy Dutystation, intermediate—

Request a price and lead time

IEC 60099-4 distribution surge arresters for 2.5–36 kV networks. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What system voltages do the arresters suit?

Distribution networks from 2.5 kV to 36 kV.

Which standard are they built to?

IEC 60099-4, in the Distribution Medium and Distribution High classes.

Is there a version for fitting inside a transformer?

Yes, the Under Oil group is meant for installation inside oil-filled apparatus.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides