IEC 60099-4 distribution surge arresters for 2.5–36 kV networks
Surge arresters for medium-voltage distribution networks from 2.5 kV to 36 kV, built to IEC 60099-4 in the Distribution Medium and Distribution High classes. They keep lightning and switching overvoltages away from transformer and switchgear insulation.
- Purpose
- protection against lightning and switching overvoltages
- Standard
- IEC 60099-4
- System voltage
- 2.5–36 kV
- Classes
- Distribution Medium, Distribution High
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
System voltages from 2.5 kV up to 36 kV are covered, the usual span of medium-voltage grids designed to IEC practice. The governing standard is IEC 60099-4, with Distribution Medium and Distribution High as the main classes, and every unit is routine tested at the works, so 100% of output is checked.
The range is split into four groups. Distribution Medium and Distribution High serve overhead feeders and distribution points; Station Low suits smaller substations; Under Oil arresters are fitted inside oil-filled apparatus such as transformers.
In operation the arrester waits between phase and earth, passing only a negligible current. A lightning strike or a switching event raises the voltage, the arrester diverts the surge current to earth and holds the stress on nearby insulation within safe limits.
Fit it as close as practical to the apparatus being protected and keep the earth lead short and straight. For an enquiry, tell us the system voltage, the neutral earthing arrangement, the mounting position and the IEC 60099-4 group required, and we will propose a version and send the documentation.
Technical specifications
| Purpose | protection against lightning and switching overvoltages |
|---|---|
| Standard | IEC 60099-4 |
| System voltage | 2.5–36 kV |
| Classes | Distribution Medium, Distribution High |
| Groups | Distribution Medium, Distribution High, Station Low, Under Oil |
| Testing | routine tests on 100% of units |
How it compares with similar models
| Parameter | IEC 60099-4 distribution surge arresters for 2.5–36 kV networks | Polymer-housed distribution surge arresters to IEEE C62.11, normal and heavy duty | Station and intermediate class surge arresters to IEEE C62.11, polymer or porcelain housed | MH4 and PH4 Station High Surge Arresters to IEC 60099-4, 36–420 kV Systems |
|---|---|---|---|---|
| Purpose | protection against lightning and switching overvoltages | protection of distribution networks against lightning and switching overvoltages | protection against lightning and switching overvoltages | — |
| Standard | IEC 60099-4 | IEEE C62.11 | IEEE C62.11 | — |
| Classes | Distribution Medium, Distribution High | Normal Duty, Heavy Duty | station, intermediate | — |
Request a price and lead time
IEC 60099-4 distribution surge arresters for 2.5–36 kV networks. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What system voltages do the arresters suit?
Distribution networks from 2.5 kV to 36 kV.
Which standard are they built to?
IEC 60099-4, in the Distribution Medium and Distribution High classes.
Is there a version for fitting inside a transformer?
Yes, the Under Oil group is meant for installation inside oil-filled apparatus.