Station and intermediate class surge arresters to IEEE C62.11, polymer or porcelain housed

Substation surge arresters in the station and intermediate classes of IEEE C62.11. They carry lightning and switching surges to earth, protecting transformers and switchgear in substations and industrial plants.

Purpose
protection against lightning and switching overvoltages
Standard
IEEE C62.11
Classes
station, intermediate
Housing
polymer or porcelain

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Two housing options are offered across this range: polymer and porcelain. Which one suits a given bay depends on site conditions, the client's specification and the apparatus the arrester will stand beside.

At normal system voltage the arrester draws almost no current and has no effect on the network. When a lightning strike or a switching operation pushes the voltage up, it conducts the surge current to earth and limits the overvoltage that reaches transformers, circuit breakers and other substation plant.

The design basis is IEEE C62.11, and both substation classes, intermediate and station, are covered. Every unit goes through routine testing at the works, so 100% of production is checked before dispatch. Typical locations are utility substations and the internal networks of industrial sites.

To match an arrester to your substation, send us the system voltage, the neutral earthing arrangement, the required IEEE C62.11 class and the preferred housing material. We will then pick a suitable version from the range and supply the documentation with it.

Technical specifications

Purposeprotection against lightning and switching overvoltages
StandardIEEE C62.11
Classesstation, intermediate
Housingpolymer or porcelain
Testingroutine tests on 100% of units
Applicationsubstations, industrial sites

How it compares with similar models

ParameterStation and intermediate class surge arresters to IEEE C62.11, polymer or porcelain housedPolymer-housed distribution surge arresters to IEEE C62.11, normal and heavy dutyPDV-65 Optima Normal Duty Distribution Arresters for 2.5–36 kV NetworksIEC 60099-4 distribution surge arresters for 2.5–36 kV networks
Purposeprotection against lightning and switching overvoltagesprotection of distribution networks against lightning and switching overvoltages—protection against lightning and switching overvoltages
StandardIEEE C62.11IEEE C62.11IEEE C62.11IEC 60099-4
Classesstation, intermediateNormal Duty, Heavy Duty—Distribution Medium, Distribution High
Housingpolymer or porcelainpolymerESP polymer, grey—

Request a price and lead time

Station and intermediate class surge arresters to IEEE C62.11, polymer or porcelain housed. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which standard do these arresters follow?

They are built to the IEEE C62.11 requirements for intermediate and station class arresters.

What housing materials are available?

The range comes in polymer or porcelain housings.

Where are they normally installed?

In utility substations and industrial networks, ahead of transformers and other plant that needs surge protection.

Similar equipment from other manufacturers