Station and intermediate class surge arresters to IEEE C62.11, polymer or porcelain housed
Substation surge arresters in the station and intermediate classes of IEEE C62.11. They carry lightning and switching surges to earth, protecting transformers and switchgear in substations and industrial plants.
- Purpose
- protection against lightning and switching overvoltages
- Standard
- IEEE C62.11
- Classes
- station, intermediate
- Housing
- polymer or porcelain
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Two housing options are offered across this range: polymer and porcelain. Which one suits a given bay depends on site conditions, the client's specification and the apparatus the arrester will stand beside.
At normal system voltage the arrester draws almost no current and has no effect on the network. When a lightning strike or a switching operation pushes the voltage up, it conducts the surge current to earth and limits the overvoltage that reaches transformers, circuit breakers and other substation plant.
The design basis is IEEE C62.11, and both substation classes, intermediate and station, are covered. Every unit goes through routine testing at the works, so 100% of production is checked before dispatch. Typical locations are utility substations and the internal networks of industrial sites.
To match an arrester to your substation, send us the system voltage, the neutral earthing arrangement, the required IEEE C62.11 class and the preferred housing material. We will then pick a suitable version from the range and supply the documentation with it.
Technical specifications
| Purpose | protection against lightning and switching overvoltages |
|---|---|
| Standard | IEEE C62.11 |
| Classes | station, intermediate |
| Housing | polymer or porcelain |
| Testing | routine tests on 100% of units |
| Application | substations, industrial sites |
How it compares with similar models
| Parameter | Station and intermediate class surge arresters to IEEE C62.11, polymer or porcelain housed | Polymer-housed distribution surge arresters to IEEE C62.11, normal and heavy duty | PDV-65 Optima Normal Duty Distribution Arresters for 2.5–36 kV Networks | IEC 60099-4 distribution surge arresters for 2.5–36 kV networks |
|---|---|---|---|---|
| Purpose | protection against lightning and switching overvoltages | protection of distribution networks against lightning and switching overvoltages | — | protection against lightning and switching overvoltages |
| Standard | IEEE C62.11 | IEEE C62.11 | IEEE C62.11 | IEC 60099-4 |
| Classes | station, intermediate | Normal Duty, Heavy Duty | — | Distribution Medium, Distribution High |
| Housing | polymer or porcelain | polymer | ESP polymer, grey | — |
Request a price and lead time
Station and intermediate class surge arresters to IEEE C62.11, polymer or porcelain housed. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which standard do these arresters follow?
They are built to the IEEE C62.11 requirements for intermediate and station class arresters.
What housing materials are available?
The range comes in polymer or porcelain housings.
Where are they normally installed?
In utility substations and industrial networks, ahead of transformers and other plant that needs surge protection.