EVP Polymer Station Arresters, IEC Station Medium and IEEE Station Class
Solid-core metal-oxide arresters in ESP polymer housings for transformer and switchgear protection in substations. They rank as station class under IEEE C62.11 and Station Medium under IEC 60099-4, with MCOV ratings starting at 2.55 kV.
- Series
- EVP
- Class
- station (IEEE); Station Medium (IEC)
- Standards
- IEEE C62.11, IEC 60099-4
- Construction
- solid core, MOV discs
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The smallest unit in the line, EVP0003003001, gives a good idea of the electrical envelope. Rated 2.55 kV MCOV (Uc) with a 3 kV duty cycle rating (Ur), it withstands 101 kV lightning impulse, 84 kV switching impulse and 50 kV wet at 60 Hz. Discharge voltage climbs from 6.4 kV at 1.5 kA through 7.6 kV at 10 kA to 9.3 kV at 40 kA, and the 0.5 microsecond figure is 10.5 kV. Pressure relief is rated at 63 kA symmetrical rms.
Mechanically, that version sits on a spade top with tripod base and single eyebolt terminals. It is 9.9 in tall, 11.5 in wide and deep and weighs 13 lb. The lug is 31.75 mm thick with a 14.224 mm hole, and the bolt circle can vary from 8.75 to 10 in. At sea level allow at least 114 mm from centreline to earth and 229 mm between phase centrelines; the unit is rated for altitudes up to 12000 ft.
Internally there are no air gaps, just MOV discs in a grey ESP polymer housing with a maximum cantilever of 20000 in lbs. A sealing system protects the stack from moisture, and every arrester is routine tested before dispatch. The family complies with the latest revisions of IEEE C62.11 and IEC 60099-4 and works on 48–62 Hz systems.
Further EVP catalogue numbers step up in MCOV and offer other mounting arrangements, so the series can be matched to the bay layout as well as the voltage. Tell us the MCOV and mounting you need and we will confirm the exact part.
Technical specifications
| Series | EVP |
|---|---|
| Class | station (IEEE); Station Medium (IEC) |
| Standards | IEEE C62.11, IEC 60099-4 |
| Construction | solid core, MOV discs |
| Housing | ESP polymer, grey |
| Frequency | 48–62 Hz |
| Max cantilever | 20000 in lbs |
| MCOV / Ur (EVP0003003001) | 2.55 kV / 3 kV |
| Pressure relief | 63 kA |
| Leakage distance (EVP0003003001) | 498 mm |
| Lightning impulse withstand | 101 kV |
| Discharge voltage at 10 kA (EVP0003003001) | 7.6 kV |
| Maximum altitude | 12000 ft |
| Bolt circle | 8.75–10 in |
Request a price and lead time
EVP Polymer Station Arresters, IEC Station Medium and IEEE Station Class. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
How is EVP classified under IEC rules?
It is a Station Medium arrester to IEC 60099-4 and a station-class unit to IEEE C62.11.
What clearances does EVP0003003001 need?
At sea level at least 114 mm from centreline to earth and 229 mm between phase centrelines.
What discharge voltage does the 2.55 kV unit give at high current?
7.6 kV at 10 kA, 8.2 kV at 20 kA and 9.3 kV at 40 kA.