215PLA and 225PLA parkingstand arresters for 15 kV and 25 kV underground networks
The 215PLA and 225PLA series are shielded polymer arresters fitted to the parkingstand bracket of an underground transformer or cabinet. They meet IEEE Std. 386 and IEEE Std. C62.11 section 8.1, and are fully insulated and suitable for submersion.
- Type
- deadfront parkingstand arrester
- Voltage class
- 15 kV (215PLA), 25 kV (225PLA)
- MCOV
- 2.55; 5.1; 7.65; 8.4; 10.2; 12.7 kV
- Duty cycle voltage
- 3; 6; 9 kV (215PLA03, 06, 09)
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
A parkingstand arrester protects the open end of a cable line in underground distribution networks against overvoltages. It is fitted phase by phase to a parkingstand bracket on a transformer at site or in a sectionalising cabinet, where the line ends, and it limits the reflected surge on the open end of the cable. The design is deadfront, so there are no exposed live parts on the surface.
The polymer housing is fully shielded and insulated, and can operate in flooded vaults. Earthing is made with a flexible 36 inch lead. The manufacturer states that the arrester is interchangeable with other products that meet the same IEEE Std. 386 requirements, so it can be installed on existing brackets without modification.
The 15 kV class covers 215PLA03, 215PLA06, 215PLA09 and 215PLA10, with MCOV values of 2.55, 5.1, 7.65 and 8.4 kV. The duty cycle voltage of the first three is 3, 6 and 9 kV, and their maximum switching surge is 8.5, 17.0 and 23.0 kV. The 15 kV models measure 12.688 x 9.625 x 4.625 inch and weigh 4.600 lb. The 25 kV class includes 225PLA09, 225PLA10, 225PLA12 and 225PLA15, with MCOV values of 7.65, 8.4, 10.2 and 12.7 kV. Their dimensions are 8.55 x 3.625 inch, with a height from 12.875 to 14.25 inch.
Residual voltage for 215PLA03 is 9.8 kV at 1.5 kA, 12.3 kV at 10 kA and 18.5 kV at 40 kA. The same current points give 26.8 kV, 33 kV and 50.5 kV for 215PLA09. The maximum installation altitude is 6000 ft above sea level. MCOV is selected for the highest continuous phase-to-earth voltage at the point of installation.
Technical specifications
| Type | deadfront parkingstand arrester |
|---|---|
| Voltage class | 15 kV (215PLA), 25 kV (225PLA) |
| MCOV | 2.55; 5.1; 7.65; 8.4; 10.2; 12.7 kV |
| Duty cycle voltage | 3; 6; 9 kV (215PLA03, 06, 09) |
| Maximum switching surge | 8.5; 17.0; 23.0 kV |
| Residual voltage 215PLA03 | 9.8 kV at 1.5 kA; 18.5 kV at 40 kA |
| Residual voltage 215PLA09 | 26.8 kV at 1.5 kA; 50.5 kV at 40 kA |
| Bracket | parkingstand bracket |
| Earthing | 36 in lead |
| Material | polymer |
| Dimensions 215PLA | 12.688 x 9.625 x 4.625 in |
| Dimensions 225PLA | 8.55 x 3.625 x 12.875 to 14.25 in |
| Weight 215PLA | 4.600 lb |
| Installation altitude | up to 6000 ft |
| Standards | IEEE Std. 386, IEEE Std. C62.11 section 8.1 |
Part numbers
Show all part numbers (8)
215PLA03, 215PLA06, 215PLA09, 215PLA10, 225PLA09, 225PLA10, 225PLA12, 225PLA15
Request a price and lead time
215PLA and 225PLA parkingstand arresters for 15 kV and 25 kV underground networks. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Where is the parkingstand arrester installed?
On the parkingstand bracket of a site transformer or sectionalising cabinet, at the point where the cable line ends. It limits overvoltage on the open end of the cable.
How is MCOV selected?
By the highest continuous phase-to-earth voltage in the network. For the 15 kV class MCOV values of 2.55, 5.1, 7.65 and 8.4 kV are available, and for the 25 kV class 7.65, 8.4, 10.2 and 12.7 kV.
Can the arrester be used in flooded vaults?
Yes. The housing is fully shielded and insulated and can be submerged. The design meets IEEE Std. 386.