NGLA (SBKC) line surge arresters for overhead lines up to 362 kV

Gapless NGLA line surge arresters based on the SBKC series for protecting overhead lines up to 362 kV from lightning overvoltages. They are installed on sections with high tower footing resistance, without a shield wire or with increased lightning activity.

Highest system voltage Us
SBKC size 0 - 170 kV; size II - 362 kV
Rated voltage Ur
up to 144 / 360 kV
Nominal discharge current In
10 / 20 kA
Specific energy capability
4.5 / 9.2 kJ/kV Ur

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The SBKC size 0 version is rated for Us 170 kV, size II for 362 kV, with rated voltage Ur up to 144 / 360 kV. Nominal discharge current In is 10 / 20 kA, the specific energy capability 4.5 / 9.2 kJ/kV Ur, and the line discharge class 2 / 4. Short-circuit current at pressure relief is 40 / 63 kA, and the mechanical load SSL is 1.2 / 4 kN·m. Clamps and fittings for line mounting are included.

Technical specifications

Highest system voltage UsSBKC size 0 - 170 kV; size II - 362 kV
Rated voltage Urup to 144 / 360 kV
Nominal discharge current In10 / 20 kA
Specific energy capability4.5 / 9.2 kJ/kV Ur
Line discharge class2 / 4
Short-circuit current (pressure relief)40 / 63 kA
Mechanical load SSL1.2 / 4 kN·m

Request a price and lead time

NGLA (SBKC) line surge arresters for overhead lines up to 362 kV. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8535 40 00 00
HS, 6 digits8535 40
CN (EU)8535 40 00
HTSUS (USA)8535 40 00 00
China customs tariff8535 40 00 00

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

Which lines are the NGLA suitable for?

For overhead lines with Us 170 kV (SBKC size 0) and 362 kV (size II).

What discharge current and energy capability do the line arresters have?

Nominal discharge current In 10 / 20 kA, specific energy capability 4.5 / 9.2 kJ/kV Ur.

Where is it advisable to install line arresters?

On overhead line sections with high tower footing resistance, without a shield wire or with increased lightning activity.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides