Parkingstand Surge Arresters 215PLA12, 225PLA18 and 225PLA21 for 15 and 25 kV

These deadfront arresters mount on the parkingstand bracket of transformers and distribution points in underground networks. Three models cover the 15 kV and 25 kV classes, with MCOV ratings of 10.2 kV, 15.3 kV and 17 kV in a fully shielded polymer housing.

Type
Parkingstand Arrester, Underground Arresters
Voltage class
15 kV (215PLA12), 25 kV (225PLA18, 225PLA21)
MCOV
10.2 kV, 15.3 kV, 17 kV
Duty cycle
12 kV, 18 kV, 21 kV

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Parkingstand arresters protect medium-voltage cable networks from lightning and switching overvoltages. The unit is mounted on the parkingstand bracket of a transformer or distribution point, where it operates at the open end of a cable run, a location where an overvoltage wave reflects and can build up. Both temporary and permanent installations are suitable.

The polymer housing is fully shielded and insulated, and the unit can be submerged. The arresters meet IEEE Std. 386 and IEEE Std. C62.11, Section 8.1, and they are interchangeable with other products meeting the same requirements. Earthing is made with a 36 in line lead, and the maximum operating altitude is 6000 ft.

The 215PLA12 is rated for the 15 kV class, with an MCOV of 10.2 kV and a duty cycle of 12 kV. Its maximum switching surge is 34.0 kV, and its residual voltage is 39 kV at 1.5 kA, 49 kV at 10 kA and 74 kV at 40 kA.

The 225PLA18 and 225PLA21 belong to the 25 kV class. The 225PLA18 has an MCOV of 15.3 kV, a duty cycle of 18 kV and a maximum switching surge of 46.0 kV, with residual voltage of 52 kV at 1.5 kA and 66 kV at 10 kA. The 225PLA21 has an MCOV of 17 kV, a duty cycle of 21 kV and a switching surge of 49.0 kV, with residual voltage of 55 kV at 1.5 kA and 73 kV at 10 kA. The 225PLA18 is 8.55 in by 3.625 in by 14.75 in, the 225PLA21 has a height of 15.385 in with the same length and width, and both weigh 4.600 lb.

The choice of model depends on the system voltage and the neutral earthing arrangement, and the MCOV must not be lower than the highest continuous voltage the arrester will see. To select the right unit, state the nominal system voltage, the method of neutral earthing and the type of parkingstand bracket interface.

Technical specifications

TypeParkingstand Arrester, Underground Arresters
Voltage class15 kV (215PLA12), 25 kV (225PLA18, 225PLA21)
MCOV10.2 kV, 15.3 kV, 17 kV
Duty cycle12 kV, 18 kV, 21 kV
Maximum switching surge34.0 kV, 46.0 kV, 49.0 kV
Residual voltage 215PLA1239 kV @ 1.5 kA, 41 kV @ 3 kA, 44 kV @ 5 kA, 49 kV @ 10 kA, 57 kV @ 20 kA, 74 kV @ 40 kA
Residual voltage 225PLA1852 kV @ 1.5 kA, 56 kV @ 3 kA, 60 kV @ 5 kA, 66 kV @ 10 kA, 78 kV @ 20 kA, 101 kV @ 40 kA
Residual voltage 225PLA2155 kV @ 1.5 kA, 60 kV @ 3 kA, 64 kV @ 5 kA, 73 kV @ 10 kA, 84 kV @ 20 kA, 107 kV @ 40 kA
MaterialPolymer
Earthing36 in line lead
BracketParkingstand Bracket
Maximum operating altitude6000 ft
Dimensions 225PLA188.55 in x 3.625 in x 14.75 in
Dimensions 225PLA218.55 in x 3.625 in x 15.385 in
Weight 225PLA18, 225PLA214.600 lb.
StandardsIEEE Std. 386, IEEE Std. C62.11 Section 8.1

Part numbers

Show all part numbers (3)

215PLA12, 225PLA18, 225PLA21

Request a price and lead time

Parkingstand Surge Arresters 215PLA12, 225PLA18 and 225PLA21 for 15 and 25 kV. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How do the 225PLA18 and 225PLA21 differ?

Both are rated for the 25 kV class, but the 225PLA18 has an MCOV of 15.3 kV and a duty cycle of 18 kV, while the 225PLA21 has an MCOV of 17 kV and a duty cycle of 21 kV. The 225PLA21 therefore has a higher residual voltage: 73 kV at 10 kA against 66 kV for the 225PLA18.

Which standards do the arresters comply with?

IEEE Std. 386 covers the separable connector interface, and IEEE Std. C62.11, Section 8.1, covers the arrester characteristics.

What is the maximum operating altitude?

The manufacturer gives a maximum operating altitude of 6000 ft. The housing is fully shielded and suitable for submersible operation.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides