TOTUS G9 — comprehensive online transformer monitor: 9-gas DGA + moisture, PD, bushing and TFC options
TOTUS G9 is a modular online power transformer monitor with DGA on a nine-gas profile and oil moisture content. It is installed on the most critical substation and power plant transformers and, if needed, supplemented with PD, bushing, through-fault current and OLTC modules.
- DGA
- 9 gases + oil moisture content
- Modules (options)
- partial discharge (PD), bushing monitoring (BM, 3/6/9 bushings), through-fault currents (TFC), OLTC
- Analytics
- thermal model, moisture in paper insulation, loading capability, insulation ageing
- Arc diagnostics
- arc phase and winding, event count, PD Triangle
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
TOTUS G9 sits at the top of the manufacturer's modular range. In it, G1 is intended for the mass fleet, G5 for important sites, and G9 is installed on transformers whose failure costs the most. These are generator step-up transformers of power plants, autotransformers of main substations, and supply nodes of wind farms, solar plants and data centres. The basis of the monitor is online analysis of dissolved gases together with moisture content. Such a set is enough to recognise overheating, partial and arc discharges, and degradation of cellulose insulation.
The monitor is expanded with modules without replacing the base unit. The bushing module (BM) works with 3, 6 or 9 bushings and monitors capacitance, tan delta, leakage current and its phase, temperature and load. The partial discharge module catches insulation defects at an early stage. Patented algorithms separate discharges in the bushings and in the tank and cut off interference, and the PD Triangle diagram shows by colour the presence, intensity and phase of the activity. The TFC module records through-fault currents, after which mechanical stresses remain in the windings and the insulation ages faster. OLTC monitoring is available separately.
The manufacturer stresses arc diagnostics. An ordinary DGA monitor sees only the growth of acetylene, the main marker of high-energy D2 discharges. TOTUS compares the stepwise growth of acetylene with high-energy events of the PD module, determines the phase and winding where the arc occurred, and keeps a count of such events. In the brochure example, the PD Triangle pointed to phase H3 of the HV winding, and the nature of the discharges to an object at floating potential, so the inspection of the transformer started with this phase immediately.
Analytical models (thermal, moisture, load, insulation ageing) calculate the hot-spot temperature, permissible overload, moisture in paper insulation and remaining life. Data go to the TOTUSPro software and to the Sapient Asset Insights platform, which brings together health indices across the whole fleet. A single hardware base for all modules simplifies operation and reduces the total cost of ownership, and the company's service adds expert support when analysing alarms. The company's article on transformer condition assessment describes a hybrid condition index method following CIGRE 761 guidance, where a condition group from 1 to 5 is combined with an overall health index from 0.00 to 0.99.
Technical specifications
| DGA | 9 gases + oil moisture content |
|---|---|
| Modules (options) | partial discharge (PD), bushing monitoring (BM, 3/6/9 bushings), through-fault currents (TFC), OLTC |
| Analytics | thermal model, moisture in paper insulation, loading capability, insulation ageing |
| Arc diagnostics | arc phase and winding, event count, PD Triangle |
| Software | TOTUSPro, Sapient Asset Insights |
Request a price and lead time
TOTUS G9 — comprehensive online transformer monitor: 9-gas DGA + moisture, PD, bushing and TFC options. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Customs codes
| UKTZED (Ukraine) | 9027 50 00 00 |
|---|---|
| HS, 6 digits | 9027 50 |
| CN (EU) | 9027 50 00 |
| HTSUS (USA) | 9027 50 80 60 |
| China customs tariff | 9027 50 00 90 |
Codes are for reference: the final code is determined at declaration for the specific model.
Questions and answers
How many gases does TOTUS G9 analyse?
The monitor measures 9 dissolved gases and oil moisture content. This is enough to recognise overheating, partial and arc discharges and cellulose ageing.
How many bushings can be connected to the BM module?
The bushing module monitors 3, 6 or 9 bushings. It measures capacitance, tan delta, leakage current and its phase.
How does G9 differ from G1 and G5?
G1 measures hydrogen and moisture for the mass fleet, G5 analyses 5 gases for important sites. G9 gives the full 9-gas profile and is installed on critical transformers.