International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

TOTUS G5 — online 5-gas DGA monitor plus moisture (photoacoustic spectroscopy) for critical transformers

TOTUS G5 is an online monitor of gases dissolved in oil for critical power transformers. It measures 5 gases and moisture content continuously by photoacoustic spectroscopy and shows trends on a touchscreen and in a browser.

Gases
H2, CH4, C2H4, C2H2, CO
Moisture
moisture content of the oil
Method
photoacoustic spectroscopy (PAS)
Interface
touchscreen, remote access via browser

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

TOTUS G5 sits in the middle of the company's range of DGA monitors. It is installed on critical power transformers where a hydrogen sensor alone is no longer enough, but the full nine-gas profile is not yet required. Typical sites are transformers of distribution and transmission networks, power plants, and wind and solar farms. The monitor measures hydrogen, methane, ethylene, acetylene, carbon monoxide and oil moisture content around the clock.

Each gas points to its own group of faults. Hydrogen responds to almost any damage, methane and ethylene indicate thermal faults, acetylene indicates high-energy discharges and arcing, and carbon monoxide points to involvement of cellulose insulation. Measurement is carried out by photoacoustic spectroscopy (PAS), which the manufacturer describes as highly accurate and stable. Alarms are raised only when a real problem appears, so the maintenance schedule is built on condition rather than on the calendar.

The built-in software with a touchscreen shows trends right at the substation, without a laptop or a separate application. DGA results are also available remotely from any browser. For fleet-wide analysis the data is passed to the TOTUSPro software and the Sapient Asset Insights platform, where it is combined into a risk assessment. The interface is clear to operating staff, so the condition of the transformer can be assessed immediately during a substation round.

G5 is expanded with the same modules as the other TOTUS monitors. These are monitoring of partial discharges, bushings (BM) and through-fault currents (TFC), and analytical models, including thermal, moisture, load and insulation ageing models. They calculate the hot-spot temperature, overload capability and moisture in the paper insulation. The architecture and interface are common to the whole platform, so monitoring can be extended without replacing the monitor.

The company's case study collections describe how TOTUS DGA monitors work in utilities. One example concerns a 31.5 MVA transformer of a European distribution company. After the monitor was installed in December 2017, gas generation (H2) was noticed and oil crossover between the OLTC and the main tank was suspected. A repair was planned, and afterwards the same monitor confirmed that no new gases were being formed, and the transformer was left in service for longer. Another case, from an Italian transmission company, describes PD fluctuations of very high energy, above 20 V and above 80 nC, which the TOTUS monitor recorded in real time.

Technical specifications

GasesH2, CH4, C2H4, C2H2, CO
Moisturemoisture content of the oil
Methodphotoacoustic spectroscopy (PAS)
Interfacetouchscreen, remote access via browser
OptionsPD, bushing monitoring (BM), through-fault currents (TFC), analytics

Request a price and lead time

TOTUS G5 — online 5-gas DGA monitor plus moisture (photoacoustic spectroscopy) for critical transformers. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)9027 50 00 00
HS, 6 digits9027 50
CN (EU)9027 50 00
HTSUS (USA)9027 50 80 60
China customs tariff9027 50 00 90

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

Which gases does TOTUS G5 measure?

Hydrogen H2, methane CH4, ethylene C2H4, acetylene C2H2 and carbon monoxide CO. The monitor also measures the moisture content of the oil.

What method is used to measure the gases?

Photoacoustic spectroscopy (PAS) is used. Measurement is continuous, around the clock.

Can G5 be extended with bushing and PD monitoring?

Yes, G5 is extended with modules for partial discharges, BM bushings and TFC through-fault currents. The base monitor does not need to be replaced for this.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides