TM1 Online Dissolved Hydrogen Monitor for Transformer Oil, 20 to 10000 ppm
The TM1 measures the dissolved hydrogen content of transformer oil continuously, showing developing faults between routine oil samples. Its solid-state sensor sits directly in the oil, and the unit needs no membranes, consumables or scheduled sensor replacement.
- Model
- TM1
- DGA method
- Solid-state H2 sensor immersed in oil
- Hydrogen range
- 20–10000 ppm
- Accuracy
- ±15% or ±20 ppm
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The monitor is intended for oil-immersed transformers in the 38–138 kV class, particularly in distribution networks where many similar machines are installed. It is fitted to new transformers and to units already in service, as well as to industrial and renewable energy transformers. Hydrogen forms in most tank faults, so its trend reveals a developing fault before it leads to failure.
Measurement is carried out by a solid-state H2 sensor immersed directly in the oil. The sensor measures hydrogen selectively, free from cross-interference by other dissolved gases. Analysis runs every 30 minutes, and data is stored for up to five years. An optional module measures moisture in the oil over the range 0–100 % RS with an accuracy of ±5 %, and oil temperature too.
The hydrogen range is 20–10000 ppm, with an error of ±15 % or ±20 ppm, repeatability of ±5 % or ±10 ppm, and a lower detection limit of 20 ppm. Three 4–20 mA analogue outputs carry the hydrogen level, the rate of change and, optionally, moisture, while two 4–20 mA analogue inputs take signals from other sensors. Three DGA alarm relays and two power and service relays switch up to 3 A at 150 VDC or 300 VAC.
Communication is through RS-232, RS-485 and USB 2.0 ports, using DNP3 and Modbus protocols. Set-up is performed with a configuration program on a PC, and results are reviewed in the TM View software. The monitor is compatible with mineral oil and ester-based insulating liquids.
The unit is mounted permanently on the transformer. The NEMA 4X / IP66 enclosure measures 23.4 × 25.1 × 31.2 cm and weighs 4 kg. Ambient operating temperature runs from −50 to +55 °C, oil temperature from −20 to +105 °C, and oil inlet pressure from 0 to 100 psi (0 to 7 bar). Power is 100–240 V AC, 50/60 Hz, drawing up to 0.8 A. Turnkey installation is available, including training in TM View.
Technical specifications
| Model | TM1 |
|---|---|
| DGA method | Solid-state H2 sensor immersed in oil |
| Hydrogen range | 20–10000 ppm |
| Accuracy | ±15% or ±20 ppm |
| Repeatability | ±5% or ±10 ppm |
| Analysis interval | Every 30 minutes |
| Moisture in oil (option) | 0–100% RS, ±5% |
| Analogue outputs | 3 × 4–20 mA |
| Analogue inputs | 2 × 4–20 mA |
| Relays | 3 DGA alarm relays, 2 power and service relays; 3 A, 150 VDC or 300 VAC |
| Interfaces | RS-232, RS-485, USB 2.0 |
| Protocols | DNP3, Modbus |
| Compatible fluids | Mineral oil, ester-based liquids |
| Oil temperature | −20…+105 °C |
| Operating temperature | −50…+55 °C |
| Oil inlet pressure | 0–100 psi (0–7 bar) |
| Enclosure | NEMA 4X / IP66, 23.4 × 25.1 × 31.2 cm, 4 kg |
| Power supply | 100–240 V AC, 50/60 Hz, 0.8 A |
| Standards | EN 61326-1, IEC 61010-1, IEC 61010-2-81, IEC 60255-21-1, CSA-C22.2 No. 61010-1-04 |
Part numbers
Show all part numbers (1)
TM1
Request a price and lead time
TM1 Online Dissolved Hydrogen Monitor for Transformer Oil, 20 to 10000 ppm. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Does the sensor need replacing or servicing?
The solid-state sensor is immersed in the oil and has no membranes or consumables, and no scheduled sensor replacement is needed.
Which transformers is the TM1 suited to?
Transformers in the 38–138 kV class, oil-immersed with mineral oil or ester-based fluids, both new units and those already in service.
How does the monitor pass data to SCADA?
Through RS-232, RS-485 or USB 2.0 using DNP3 and Modbus, and through three 4–20 mA analogue outputs and alarm relays.