International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

TGA-B Instrument for Stator Partial Discharge Testing, 0.1 to 350 MHz

The TGA-B is used for periodic online measurement of partial discharges in motors and in 50/60 Hz turbogenerators and hydrogenerators fitted with permanent 80 pF epoxy-mica capacitor sensors. The TGA-B version works with sensors installed on the machine's busbar.

Type
portable partial discharge monitoring instrument
Machines
motors, turbogenerators, 50/60 Hz hydrogenerators
Sensors
80 pF EMC (6.9 kV to 35 kV) and/or SSC
Frequency band
0.1 to 350 MHz

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Partial discharges accompany most processes that destroy the insulation of a stator winding. Measuring them reveals windings that are weakened, contaminated, overheated or poorly impregnated, and helps assess the risk of stator damage. Measurement is made on a machine in operation without stopping it, and station staff carry out the measurements and interpret the results after brief training. The method is recommended by IEEE Std. 1434-2000, IEEE Std. 1129 and IEC 60034-27-2.

The instrument connects to permanently installed 80 pF epoxy-mica capacitor sensors (EMC) for machines rated 6.9 kV to 35 kV. A high measurement frequency and a good signal-to-noise ratio allow partial discharges and electrical interference to be separated and recorded automatically. The frequency band is 0.1 to 350 MHz, the shortest pulse duration (FWHM) is less than 2.5 ns at the 3 dB level, and there are 100 phase windows per cycle, pulse amplitudes from 2 to 34000 mV, 10 sensitivity settings, and a data acquisition time of 1 s or 5 s per amplitude window.

A computer running the manufacturer's software controls the instrument and displays the data. The instrument automatically calculates the peak discharge amplitude (Qm), which is used to judge how far discharges have developed and the likely causes of winding deterioration, and to compare the relative condition of machines of the same type. The instrument is set at the factory for the specific machine type.

The series has several versions: TGA-B for EMC sensors on the busbar, TGA-BP for EMC sensors on the busbar and on the hydrogenerator, TGA-S for stator slot couplers (SSC), TGA-SB for SSC and busbar EMC sensors, and TGA-SP for SSC and hydrogenerator EMC sensors. For turbogenerators with slot sensors, the version with the letter S is selected.

Operating temperature is -15 °C to 45 °C, with relative humidity up to 95 % non-condensing. The instrument is supplied in a 41 × 31 × 21 cm case weighing 10 kg. For continuous monitoring of the same machines, fixed monitoring systems integrated with the station's SCADA can be used instead of periodic measurements with a portable instrument.

Technical specifications

Typeportable partial discharge monitoring instrument
Machinesmotors, turbogenerators, 50/60 Hz hydrogenerators
Sensors80 pF EMC (6.9 kV to 35 kV) and/or SSC
Frequency band0.1 to 350 MHz
Shortest pulse duration (FWHM)less than 2.5 ns at 3 dB
Phase windows100 per cycle
Pulse amplitude range2 to 34000 mV
Sensitivity settings10
Data acquisition time1 s or 5 s per amplitude window
Operating temperature-15 °C to 45 °C
Relative humidityup to 95 % non-condensing
Case dimensions41 × 31 × 21 cm
Weight10 kg
StandardsIEEE Std. 1434-2014, IEEE Std. 1129, IEC 60034-27-2:2012

Part numbers

Show all part numbers (5)

TGA-B, TGA-BP, TGA-S, TGA-SB, TGA-SP

Request a price and lead time

TGA-B Instrument for Stator Partial Discharge Testing, 0.1 to 350 MHz. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Does the machine have to be stopped for measurement?

No. Measurements are made online on a machine in operation, through permanently installed sensors.

Which version should be chosen for a hydrogenerator?

TGA-BP for EMC sensors on the busbar and on the hydrogenerator, or TGA-SP if slot sensors (SSC) are also installed.

Which sensors suit the TGA-B?

80 pF epoxy-mica capacitor sensors (EMC) permanently installed on the busbar of machines rated 6.9 kV to 35 kV.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides