Calisto R9 Infrared DGA Monitor with Water-Vapour Calibration for Nine Gases
A multi-gas online dissolved gas monitor for transformers that uses infrared photoacoustic spectroscopy and keeps its accuracy through automatic water-vapour calibration. It removes the need for calibration gas cylinders and holds its accuracy over the service life.
- Type
- online dissolved gas analysis (DGA) monitor, infrared
- Measurement method
- DIPAS (differential infrared photoacoustic spectroscopy), thermal conductivity for H2
- Gases measured
- hydrogen, carbon monoxide, methane, acetylene, ethylene, ethane, carbon dioxide, oxygen, nitrogen
- Moisture
- yes
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The R9 measures hydrogen, carbon monoxide, methane, acetylene, ethylene, ethane, carbon dioxide, oxygen, nitrogen and moisture in the oil of power transformers. It supplies the data needed for early fault detection, accurate diagnosis and risk assessment, and it can raise automatic alarms when the condition of the transformer changes.
Gases are measured using the differential infrared photoacoustic spectroscopy (DIPAS) method, while hydrogen is determined with proprietary thermal conductivity technology. The approach is sensitive to small dissolved gas concentrations and gives stable readings. Calibration runs automatically on board, using water vapour as the calibrant, so compressed gas cylinders never need replacing and the time and cost of upkeep stay low.
Gas is drawn out of the oil through a membrane that tolerates vacuum. The membrane keeps oil and oil vapours out of the measuring system for the whole service life, including during maintenance on the transformer or the monitor. The pump tolerates sludge, so oil filtration is not needed, and precise thermal control supports the accuracy of the readings. An intelligent bubble trap removes air and gas from the oil before it returns to the tank, protecting the transformer's dielectric system, and installation usually takes under 2 hours.
The R9 software runs in any common web browser, where the monitor is set up and historic readings and alarm settings are viewed. Data can be moved to the manufacturer's platforms for in-depth DGA diagnostics. Communication uses DNP3 and Modbus, with IEC 61850 available as an option, and the unit is designed and tested against cyber security requirements and international standards for EMC, safety, environmental conditions and vibration.
Technical specifications
| Type | online dissolved gas analysis (DGA) monitor, infrared |
|---|---|
| Measurement method | DIPAS (differential infrared photoacoustic spectroscopy), thermal conductivity for H2 |
| Gases measured | hydrogen, carbon monoxide, methane, acetylene, ethylene, ethane, carbon dioxide, oxygen, nitrogen |
| Moisture | yes |
| Calibration | automatic, using water vapour, no gas cylinders |
| Gas extraction | membrane, vacuum tolerant |
| Pump | sludge tolerant, no oil filtration needed |
| Bubble protection | automatic removal of air and gas from the oil |
| Interface | web interface in a browser |
| Communication protocols | DNP3, Modbus, IEC 61850 (optional) |
| Standards | EMC, safety, environmental conditions, vibration |
| Installation time | usually less than 2 hours |
Request a price and lead time
Calisto R9 Infrared DGA Monitor with Water-Vapour Calibration for Nine Gases. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Does the R9 need calibration gas cylinders?
No. The R9 calibrates automatically using water vapour, so gas cylinders are not used.
Can oil get into the measuring system?
No. Gas is extracted through a membrane that keeps oil and oil vapours out of the measuring system, including during maintenance.
How long does installation take?
Installation usually takes less than 2 hours, and the bubble trap removes air and gas from the oil automatically before it returns to the tank.
Similar equipment from other manufacturers