International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

QBM online bushing monitor for tan δ and capacitance, up to 6 bushings

The QBM is a continuous monitoring system for the loss tangent tan δ (PF) and capacitance of high-voltage bushings at substations. It measures the phase shift created by the capacitive insulation layers of a bushing and predicts insulation defects from the rate at which that shift changes.

Type
online bushing monitor
Parameters
tan δ (PF), capacitance
Method
phase shift of capacitive layers, rate of change
Number of bushings
1 to 6, independent

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Operation and data review are handled through a web browser, so no separate program is needed. The interface shows trends, a data log and a summary status panel, while alarms and messages are generated in real time. Settings and monitoring can be reached remotely, and mounting and configuration options are chosen to suit each site. The system is built into the wider transformer condition monitoring arrangement.

The measurement relies on the phase difference introduced by the capacitive layers of the bushing. The system calculates the rate of change of tan δ and capacitance, and uses that value to estimate how a defect is developing. Each bushing is monitored separately, without a reference second bushing. The design is intended for demanding environmental conditions and resists interference.

A single unit serves between 1 and 6 bushings independently. One spare module is provided for expansion with analogue or digital signals, and the system can be extended and upgraded on site without reconfiguration. Third-party devices and the maker's other transformer monitors can be connected, including dissolved gas analysers, UHF partial discharge recording systems and air dryers.

The unit is installed on the bushings of power transformers to follow insulation condition in service and to receive early warning of internal faults before failure. It detects defects linked to partial breakdown of layers, moisture, poor contacts and ageing of insulating material, as well as signs of partial discharge in the bushings. The data supports condition-based maintenance and cuts unplanned outages.

Technical specifications

Typeonline bushing monitor
Parameterstan δ (PF), capacitance
Methodphase shift of capacitive layers, rate of change
Number of bushings1 to 6, independent
Reference bushingnot required
Defects detectedpartial breakdown, moisture, poor contacts, insulation ageing
Expansion1 spare module (analogue or digital signal)
Interfaceweb interface, no separate program
Functionstrends, data log, status panel, real-time alarms
Accessremote monitoring and settings
Integrationgas analysers, UHF systems, air dryers, third-party devices

Request a price and lead time

QBM online bushing monitor for tan δ and capacitance, up to 6 bushings. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Is a reference bushing needed to measure tan δ?

No, the system monitors each bushing separately without a second reference bushing.

How many bushings can one monitor cover?

Between 1 and 6 bushings independently, with one spare module for expansion.

Is any separate software needed to operate the system?

No, data and settings are accessed through a web browser, including remotely.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides