Pt100 Resistance Temperature Detectors for Transformer Oil and Winding Temperature
Pt100 platinum resistance sensors measure oil temperature and feed winding temperature simulation in oil-filled transformers. They connect to transformer monitors and are fitted into thermal plates and wells.
- Type
- Resistance temperature detector (RTD)
- Sensing element
- Pt100, platinum
- Nominal resistance
- 100 ohms
- Measured quantity
- Oil temperature, simulated winding temperature
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Resistance temperature detectors from this range are fitted to oil-filled transformers, where they track the temperature of the upper oil layers and feed the thermal model used to simulate winding temperature. The readings help decide how cooling is controlled, when an overheating alarm should sound and how heavily a unit can safely be loaded. Utilities and industrial plants that watch oil and winding temperature around the clock are the typical users.
The sensing element is a platinum resistor of the Pt100 type, with a nominal resistance of 100 ohms. Its resistance rises as the temperature rises, and a monitor or measuring transmitter reads that resistance and converts it into a temperature. The output is analogue and the sensor needs no power supply of its own, so it can be wired to any secondary instrument with a Pt100 input.
Several models are offered for different mounting points. Thermal plates serve winding temperature simulation systems, while wells, also called pockets, sit in the tank cover and measure the oil directly. Selection therefore starts from the type of well or thermal plate and from the monitor that will receive the signal.
The sensors work with transformer monitors, thermal plates and wells, and they fit into systems that monitor and control transformers. The construction is intended for long service in the harsh conditions of a transformer installed at an open-air substation.
To choose a model, please send the code of the existing sensor or well, the type of monitor, whether the sensor measures oil or simulates the winding, and the length of the connecting cable. The range has many configured versions, and examples of their codes are listed in the specification table.
Technical specifications
| Type | Resistance temperature detector (RTD) |
|---|---|
| Sensing element | Pt100, platinum |
| Nominal resistance | 100 ohms |
| Measured quantity | Oil temperature, simulated winding temperature |
| Application | Oil-filled transformers |
| Mounting point | Thermal plates, wells (pockets) |
| Compatibility | Transformer monitors, monitoring and control systems |
Part numbers
Show all part numbers (12)
103-018-01, 103-018-03, 103-035-01, 103-044-04, 103-047-04, 103-054-01, 103-057-01, 103002-606, 103199-026, 103298-001, 103359-001, 103773-001
Request a price and lead time
Pt100 Resistance Temperature Detectors for Transformer Oil and Winding Temperature. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which sensing element does the sensor use?
A platinum resistor of the Pt100 type with a nominal resistance of 100 ohms.
Can the sensor be used for winding temperature simulation?
Yes, models for thermal plates are used in the winding temperature simulation systems of a transformer.
What is needed to choose the right model?
The code of the existing sensor or well, the monitor type, the mounting point and the length of the connecting cable.
Similar equipment from other manufacturers